INSTALLATION

Wall drilling and bracket fixing

7.2.1

11

116

116

12a

 

 

650 min.

320 X 1÷2

Wall marking:

Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed.

Draw a horizontal line at 650 mm above the hob.

Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit align- ing the centre (notch) with the vertical reference line.

Mark the wall at the centres of the holes in the bracket.

Place bracket 7.2.1 on the wall as shown at X mm below the first bracket (X = height of the upper chimney section supplied), aligning the centre (notch) with the vertical line.

Mark the wall at the centres of the holes in the bracket.

Mark a reference point as indicated at 116 mm from the vertical reference line and 320 mm above the horizontal reference line.

Repeat this operation on the other side.

Drill ø 8 mm holes at all the centre points marked.

Insert the wall plugs 11 in the holes.

Fix the lower bracket 7.2.1 using the 12a screws (4,2 x 44,4) supplied.

Fix the upper bracket 7.2.1 and the air outlet connection support 7.3 together using the 2 screws 12a (4,2 x 44,4) supplied.

Insert the two screws 12a (4,2 x 44,4) supplied in the hood body fixing holes, leaving a gap of 5-6 mm between the wall and the head of the screw.

EN

 

1

 

16

Image 16
Contents Istruzioni per l’uso e l’installazione Indice Index Sommaire Inhaltsverzeichnis Içerikler Installazione Consigli E SuggerimentiUSO ManutenzioneCaratteristiche ComponentiInstallazione Foratura Parete e Fissaggio StaffeUscita Aria Versione Filtrante 150Montaggio Camino Connessione ElettricaCamino superiore Camino inferioreUSO Manutenzione Filtri antigrassoFiltro antiodore Versione Filtrante IlluminazioneInstallation MaintenanceRecommendations and Suggestions USECharacteristics ComponentsInstallation Wall drilling and bracket fixingRecirculation Version AIR Outlet Flue assembly Electrical ConnectionUpper exhaust flue Lower exhaust flueUSE Maintenance Light ReplacementGrease filters Activated charcoal filter Recirculation versionUtilisation Conseils ET SuggestionsEntretien Caracteristiques ComposantsPerçage Paroi et Fixation Brides Sortie AIR Version Filtrante Montage Cheminée Branchement ElectriqueCheminée supérieure Cheminée inférieureUtilisation Remplacement Lampes EntretienFiltres anti-graisse Filtre anti-odeur Version filtranteEmpfehlungen UND Hinweise MontageBedienung WartungCharakteristiken KomponentenMontage Nachstehende Linien an die Wand zeichnenBei Abluftbetrieb kann die Haube vom Installateur wahlweise Montage des HaubenkörpersAnschlüss in abluftversion Mittels Rohr oder Schlauch ø 150 oder 120 mm an die AußenKaminmontage ElektroanschlussOberer Kaminteil Unterer KaminteilBedienung Wartung FettfilterGeruchsfilter Umluftversion BeleuchtungTavsiyeler VE Öneriler MontajBoyutlar ÖzelliklerParçalar Montaj Duvarın Delinmesi ve Braketlerin SabitlenmesiFİltrelİ Modelİn Hava Çikişi Bacanın Montajı Elektrİk BağlantisiÜst Baca Alt BacaKullanim Bakim Yağ tutucu filtrelerKoku Filtresi Filtreli Model AydınlatmaPage Page 436002803ver3