ELECTRICAL CONNECTION

Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.

Remove the grease filters (see paragraph Mainte- nance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan.

Flue assembly

Upper exhaust flue

• Slightly widen the two sides of the upper flue and

hook them behind the brackets 7.2.1, making sure

2.1

that they are well seated.

 

• Secure the sides to the brackets using the 4 screws

2

12c (2,9 x 9,5) supplied.

 

• Make sure that the outlet of the extensions pieces is

2.2

aligned with the chimney outlets.

 

Lower exhaust flue

Slightly widen the two sides of the flue and hook them between the upper flue and the wall, making sure that they are well seated.

Fix the lower part laterally to the hood body using the 2 screws 12c (2,9 x 9,5) supplied.

7.2.1

12c

12c

EN

 

1

 

18

Image 18
Contents Istruzioni per l’uso e l’installazione Indice Index Sommaire Inhaltsverzeichnis Içerikler USO InstallazioneConsigli E Suggerimenti ManutenzioneCaratteristiche ComponentiInstallazione Foratura Parete e Fissaggio StaffeUscita Aria Versione Filtrante 150Camino superiore Montaggio CaminoConnessione Elettrica Camino inferioreUSO Filtro antiodore Versione Filtrante ManutenzioneFiltri antigrasso IlluminazioneRecommendations and Suggestions InstallationMaintenance USECharacteristics ComponentsInstallation Wall drilling and bracket fixingRecirculation Version AIR Outlet Upper exhaust flue Flue assemblyElectrical Connection Lower exhaust flueUSE Grease filters MaintenanceLight Replacement Activated charcoal filter Recirculation versionConseils ET Suggestions UtilisationEntretien Caracteristiques ComposantsPerçage Paroi et Fixation Brides Sortie AIR Version Filtrante Cheminée supérieure Montage CheminéeBranchement Electrique Cheminée inférieureUtilisation Filtres anti-graisse Remplacement LampesEntretien Filtre anti-odeur Version filtranteBedienung Empfehlungen UND HinweiseMontage WartungCharakteristiken KomponentenMontage Nachstehende Linien an die Wand zeichnenAnschlüss in abluftversion Bei Abluftbetrieb kann die Haube vom Installateur wahlweiseMontage des Haubenkörpers Mittels Rohr oder Schlauch ø 150 oder 120 mm an die AußenOberer Kaminteil KaminmontageElektroanschluss Unterer KaminteilBedienung Geruchsfilter Umluftversion WartungFettfilter BeleuchtungTavsiyeler VE Öneriler MontajÖzellikler BoyutlarParçalar Montaj Duvarın Delinmesi ve Braketlerin SabitlenmesiFİltrelİ Modelİn Hava Çikişi Üst Baca Bacanın MontajıElektrİk Bağlantisi Alt BacaKullanim Koku Filtresi Filtreli Model BakimYağ tutucu filtreler AydınlatmaPage Page 436002803ver3