Franke Consumer Products FMY 367 Charcoal filter ductless version, Lighting, Light Replacement

Page 13

Charcoal filter (ductless version)

This filter cannot be washed or regenerated. It must be replaced when the EF appears on the display or at least once every 4 months.

Activation of the alarm signal

In the recycling version hoods the filter saturation alarm must be activated during the instal- lation or later.

Switch off the hood and the lights.

Disconnect the hood from the main voltage supply.

After restoring the connection press and hold B-key.

When releasing the key two rotating rectangles appear on the display.

Within 3 seconds press the B-key until a flashing confirmation appears on the dispaly:

2 flashes with EF - charcoal filter saturation alarm ACTIVATED

1 flash with EF - charcoal filter saturation alarm DEACTIVATED.

REPLACING THE CHARCOAL FILTER

Reset of the alarm signal

Switch off the hood and the lighting. If the 24h-function has been activated this has to be deactivated.

Press the E-key until the display is unlit.

Replacing of the filter

Open the comfort panels pulling them downwards.

Remove the metal grease filters.

Remove the saturated charcoal filter by releasing the fixing hooks

Fit the new filter and fasten it in its correct position.

Put the metal grease filters in their seats.

Close the comfort panels.

Lighting

LIGHT REPLACEMENT

20 W halogen light.

• Remove the 2 screws fixing the Lighting support, and pull it out of from the Hood.

• Extract the lamp from the Support.

Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes.

Replace the Support, fixing it in place with the two screws re- moved as above.

EN

 

1

 

13

Image 13
Contents Mythos Index Read and Save These Instructions R N I N G R N I N G Recommendations and Suggestions InstallationUSE CareDimensions Components Dimensions and Main PartsWall drilling and bracket fixing InstallationConnections Mounting the hood bodyDucted Version AIR Exhaust System Ductless Version AIR OutletElectrical Connection Chimney assemblyUpper exhaust Chimney Lower exhaust ChimneyControl board USERemote Control Optional Cleaning the Comfort PanelsCare Metal grease filtersCharcoal filter ductless version Light ReplacementLighting Replacing the Charcoal Filter114 Table DES MatièresLire ET Conserver CES Instructions Avertissement Avertissement Utilisation Conseils ET SuggestionsEntretien Protecteur ThermiqueDimensions et Principales Pièces Perçage de la paroi et fixation des brides Branchements Montage du corps de la hotteSortie D’AIR Version Aspirante Sortie D’AIR Version FiltranteBranchement Électrique Montage de la cheminéeCheminée supérieure Cheminée inférieureUtilisation Tableaux des commandesSoin ET Entretien Télécommande EN OptionNettoyage des panneaux Comfort Filtres à graisse métalliquesRemplacement DES Ampoules Remplacement DU Filtre ANTI-ODEUR AU Charbon ActifFiltre anti-odeur au charbon actif version filtrante ÉclairagePage Page 43600386501