Franke Consumer Products FMY 367 installation instructions R N I N G

Page 4

W A R N I N G

Venting system MUST terminate outside the home.

DO NOT terminate the ductwork in an attic or other enclosed space.

DO NOT use 4" laundry-type wall caps.

Flexible-type ductwork is NOT recommended.

DO NOT obstruct the flow of combustion and ventilation air.

Failure to follow venting requirements may result in a fire.

ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A timedelay fuse or circuit breaker is recommended. The fuse must be sized per local codes in ac- cordance with the electrical rating of this unit as specified on the serial/rating plate located inside the unit near the field wiring compartment. THIS UNIT MUST BE CONNECTED WITH COP- PER WIRE ONLY. Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances. Wire size and connec- tions must conform with the rating of the appliance. Copies of the standard listed above may be obtained from:

National Fire Protection Association

Batterymarch Park

Quincy, Massachusetts 02269

This appliance should be connected directly to the fused disconnect (or circuit breaker) through flexible, armored or nonmetallic sheathed copper cable. Allow some slack in the cable so the ap- pliance can be moved if servicing is ever necessary. A UL Listed, 1/2" conduit connector must be provided at each end of the power supply cable (at the appliance and at the junction box).

When making the electrical connection, cut a 1 1/4" hole in the wall. A hole cut through wood must be sanded until smooth. A hole through metal must have a grommet.

WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, do not use this fan with

any solid-state speed control device.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Use this unit only in the manner intended by the manufac- turer. If you have any questions, contact the manufacturer.

Before servicing or cleaning unit, switch power off at service panel and lock the service discon- necting means to prevent power from being switched on accidentally. When the service discon- necting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors.

EN

 

4

 

4

Image 4
Contents Mythos Index Read and Save These Instructions R N I N G R N I N G Installation Recommendations and SuggestionsUSE CareDimensions and Main Parts Dimensions ComponentsInstallation Wall drilling and bracket fixingMounting the hood body ConnectionsDucted Version AIR Exhaust System Ductless Version AIR OutletChimney assembly Electrical ConnectionUpper exhaust Chimney Lower exhaust ChimneyUSE Control boardCleaning the Comfort Panels Remote Control OptionalCare Metal grease filtersLight Replacement Charcoal filter ductless versionLighting Replacing the Charcoal FilterTable DES Matières 114Lire ET Conserver CES Instructions Avertissement Avertissement Conseils ET Suggestions UtilisationEntretien Protecteur ThermiqueDimensions et Principales Pièces Perçage de la paroi et fixation des brides Montage du corps de la hotte BranchementsSortie D’AIR Version Aspirante Sortie D’AIR Version FiltranteMontage de la cheminée Branchement ÉlectriqueCheminée supérieure Cheminée inférieureTableaux des commandes UtilisationTélécommande EN Option Soin ET EntretienNettoyage des panneaux Comfort Filtres à graisse métalliquesRemplacement DU Filtre ANTI-ODEUR AU Charbon Actif Remplacement DES AmpoulesFiltre anti-odeur au charbon actif version filtrante ÉclairagePage Page 43600386501