Electrical connection
Hardwired electrical connection
It is possible to hardwire this appliance to an existing power cable.
CAUTION: Before servicing, disconnect the power supply by either removing the fuse, shutting off the power main or manually "tripping" the circuit breaker.
Installation work and repairs should only be performed by a qualified technician in accordance with all applicable codes and standards. Repairs and service by unqualified persons could be dangerous and the manufacturer cannot be held responsible.
Before connecting the appliance to the power supply, make sure that the voltage and frequency listed on the data plate correspond with the household electrical supply. This data must correspond to prevent machine damage. Consult an electrician if in doubt.
GROUNDING INSTRUCTIONS
THIS APPLIANCE MUST BE GROUNDED.
This appliance must be connected to a grounded metal, permanent wiring system, or an
Prior to making a hardwire connection to the terminal, remove the power cord. Otherwise there will be a risk of electric shock from the attached plug.
An existing flexible supply cord or cable shall have a minimum thickness of AWG 14.
120 V, 60 Hz, 15 A fuse rating
Black wire (live): | connect to L |
White wire (neutral): connect to N
Green wire (ground): connect to
After attaching the permanent power supply cord, check that all screws on the terminal block and the strain relief are tightened.
61