Casters (Accessory) | 
  | 
If it is necessary to disconnect the restraint, unplug electrical  | 
  | 
supply before disconnection. Reconnect the restraint before  | 
  | 
plugging the electrical supply in and returning the fryer to its  | 
  | 
installation position.  | 
  | 
Instructions for installing casters to the fryer are included with  | 
  | 
the casters.  | 
  | 
LEVELING | 
  | 
Place a carpenter's level on top of the fryer and level the fryer  | 
  | 
  | |
casters.  | Fig. 1  | 
ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL CODES.
WARNING: DISCONNECT THE ELECTRICAL POWER SUPPLY TO THE MACHINE AND FOLLOW LOCKOUT/TAGOUT PROCEDURES.
WARNING: APPLIANCES EQUIPPED WITH A 120V FLEXIBLE ELECTRIC SUPPLY CORD ARE PROVIDED WITH A 
Place fryer as near to its final position as possible. Connect 3 phase line to X, Y and Z of terminal block. To reach terminal block, remove electric cover plate from fryer.
For each 151/2" (394 mm) and 21" (533 mm) section, a 3 phase supply line capable of handling the required KW at the fryer's rated voltage (208, 480) is needed. Refer to the fryer data plate for this electrical information.
If a fan interlock is needed, it should be connected to 1 and 2 on the four pole barrier strip. 1 and 2 go to a set of dry contacts on the power switch.