Vulcan-Hart 1ER50C, ML-136499, ML-136498, ML-136497 Dispose, Temperature and Time Programming

Page 13

Dispose

The controller can also be programmed to alert the operator to dispose of the shortening by counting the number of times the shortening is filtered. When the filter count is the same as the programmed filter count, DISPOSE is displayed in the window.

PROG 00 - Enter the number of filter counts you want the controller to count before giving a dispose alert. To disable the dispose reminder, enter 99.

ACT 00 - Leave at 00 unless editing. This is the number of times the shortening has been filtered.

Turn power switch off and open the drain valve.

Discard the shortening into suitable discharge container.

Close the drain valve and fill the vat with shortening.

Turn power switch on.

Enter the programming mode, select the dispose parameter and reset the actual filter count to zero. This will also reset the actual cook count to zero.

NOTE: The dispose prompt can only be reset by resetting the actual filter count or disabling the parameter.

NOTE: The filter prompt takes precedence over dispose. See Daily Filtering section in this manual for more information.

TEMPERATURE AND TIME PROGRAMMING

Temperature

1.Press to enter program mode. PROGRAM is displayed in the window.

2.Press to enter temperature mode. 000°F and TEMP are displayed in the window.

3.Press through to enter desired fry temperature. The fry temperature is displayed in the window.

4.Press to exit the temperature mode. Press again to exit program mode completely.

Time

There are ten timers with advanced timing features on the ERC fryer for setting fry times on multiple products.

Timers through :

1.Press and enter the program mode. PROGRAM is displayed in the window.

2.Press . The LED's on timers through are lit and SELECT PRODUCT is displayed in the window.

3.To select a timer, press one of the lit timer numbers; CK# 00:00 and TIME are displayed in the window.

— 13 —

Image 13
Contents Installation FIELD-INSTALLED Accessories InstallationUnpacking Width Fry Compound Model Inches / cm Voltage Lb / kgLocation AssemblyUnited States of America CanadaLeveling Casters AccessoryElectrical Connections Before First USE OperationFilling FRY Tank with Shortening Daily Shortening AdditionControls 1ERD SeriesControl Guide Programming Guide ProgrammingMelt Options 1ERD Series Using the Fryer After StartupShutdown Extended Shutdown1ERC Series Password No PasswordRequired Dispose RecoverySet Back 275FHeating Melt L Melt S Melt Options 1ERC SeriesFilter Programming Temperature Temperature and Time ProgrammingDispose TimeSetting Advanced Time Features Advanced Time FeaturesPress the power switch off Drain the fryer Unplug the fryer Time Programming Quick Chart Frying Guidelines ALL Models Filtering ProcedureFrying Recommended maximum capacitiesDrain Interlock CleaningShortening Life DailyAlarms and Error Messages TroubleshootingService and Parts Information Maintenance