Vulcan-Hart 1ER85D, ML-136499, ML-136498, ML-136497, ML-136496, 1ER50D, 1ER50C Programming Guide

Page 7

PROGRAMMING

Temperature, time and other parameters must be set before operating. Once these parameters are set, the fryer can be operated at the touch of a button.

Press to enter the program mode and scroll through the parameters. If the Parameter Lock feature is disabled, program mode is immediate. If the Parameter Lock feature is on, LoC is displayed in the

window and program entry cannot be accessed. To access the program mode while LoC is on, press within 6 seconds of pressing . To turn the Parameter Lock feature off, see Program Guide below.

Programming Guide

Once in the program mode, the parameters are displayed in the order listed below. To exit the program

and save changes, press and hold for approximately 2 seconds.

PARAMETER

 

SELECT

DISPLAY

SCROLL

 

 

 

 

 

 

 

 

Left Timer

 

 

 

 

LED is lit above the left basket

Press

and

Press

or

to

enter time.

icon. The time value is displayed

scroll to next

 

 

 

 

 

in window.

item.

 

 

 

 

 

 

 

 

 

Right Timer

 

 

 

 

LED is lit above the right basket

Press

and

Press

or

to

enter time.

icon. The time value is displayed

scroll to next

 

 

 

 

 

in window.

item.

 

 

 

 

 

 

 

 

 

Set Temperature

Press

or

to

enter

The temperature value is

Press

and

 

 

 

 

scroll to next

 

 

 

 

displayed in window.

 

temperature.

 

 

item.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Offset

 

 

 

 

00F

Press

and

 

For service only

or

scroll to next

Calibration

 

 

 

 

 

-00F

item.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Melt Options:

Press

or

to select melt

CY L (Liquid shortening)

Press

and

or

Liquid shortening

 

 

 

 

CY S (Solid shortening)

scroll to next

Solid shortening

 

 

 

 

option.

 

 

 

or

item.

 

No melt

 

 

 

 

 

 

 

 

CY O (No melt)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy

Press

or

to select

gAS

Press

and

 

 

 

 

or

scroll to next

Source

 

 

 

 

source of heat.

 

 

ELEC

item.

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Lock

Press

or

to

lock or

LoC (Unlock Parameter)

Press

and

 

 

 

 

or

scroll to next

 

unlock program entry.

ULoC (Lock Parameter )

item.

 

 

 

 

 

 

 

 

 

Fahrenheit or

Press

or

to

 

F

Press

and

 

 

 

 

or

scroll to next

Celsius

 

 

 

 

select Fahrenheit or Celsius.

C

item.

 

 

 

 

 

 

 

 

 

 

 

— 7 —

Image 7
Contents Installation Width Fry Compound Model Inches / cm Voltage Lb / kg InstallationFIELD-INSTALLED Accessories UnpackingCanada AssemblyLocation United States of AmericaLeveling Casters AccessoryElectrical Connections Daily Shortening Addition OperationBefore First USE Filling FRY Tank with ShorteningControls 1ERD SeriesControl Guide Programming Guide ProgrammingExtended Shutdown Using the Fryer After StartupMelt Options 1ERD Series Shutdown1ERC Series Password No PasswordRequired 275F RecoveryDispose Set BackHeating Melt L Melt S Melt Options 1ERC SeriesFilter Programming Time Temperature and Time ProgrammingTemperature DisposeSetting Advanced Time Features Advanced Time FeaturesPress the power switch off Drain the fryer Unplug the fryer Time Programming Quick Chart Recommended maximum capacities Filtering ProcedureFrying Guidelines ALL Models FryingDaily CleaningDrain Interlock Shortening LifeAlarms and Error Messages TroubleshootingService and Parts Information Maintenance