Vulcan-Hart VCRG24-T operation manual Installation, Unpacking, Location

Page 3

INSTALLATION, OPERATION AND CARE OF

MEDIUM DUTY GAS GRIDDLES

GENERAL

Medium Duty Gas Griddles are produced with quality workmanship and materials. Proper installation, usage and maintenance of your griddle will result in many years of satisfactory performance.

Thoroughly read this entire manual and carefully follow all of the instructions provided.

Model

Number Of Burners

BTU/hr Input Rating

VCRG24-T / WCRG24-T

2

50,000

VCRG36-T / WCRG36-T

3

75,000

VCRG48-T / WCRG48-T

4

100,000

INSTALLATION

UNPACKING

This griddle was inspected before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of shipment. Check for possible shipping damage immediately after unpacking. If the griddle is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.

Carefully unpack your griddle and make sure that no parts are discarded with packaging material. A pressure regulator designed to operate with the griddle has been supplied and must be installed before the griddle is placed into service (Refer to GAS PRESSURE REGULATOR INSTALLATION in this manual).

LOCATION

The installation location must be kept free and clear of combustibles. When installing, never enclose the bottom of the griddle with a raised curb or other constructions that would obstruct flow of air into or out of the griddle. Adequate clearance for air openings into the combustion chamber must be provided. Make sure there is an adequate supply of air in the room to replace air taken out by the ventilation system.

Do not permit air to blow directly at the griddle. Avoid open windows next to the griddle wherever possible. Avoid wall-type fans which create air cross-currents within the room.

This griddle is Design Certified for installation on a non-combustible counter with 4” legs, or combustible floor with 24” high stand.

- 3 -

Image 3
Contents VCRG48-T ModelsImportant for Your Safety For Your SafetyInstallation UnpackingLocation Griddles Mounted on Stands with Casters Installation Codes and StandardsGAS Connections Testing the GAS Supply SystemGAS Pressure Regulator Installation Flue ConnectionsPropane GAS Conversion Controls OperationBefore First USE Seasoning the GriddleCutaway View VCRG-T / WCRG-T Pilot Lighting ProcedureProduct Using the GriddleZone Cooking ZoneOnce PER Week Cleaning the GriddleAfter Each USE Once PER DAYCalibration AdjustmentsLeveling Pilot AdjustmentMaintenance Troubleshooting ProblemPossible Causes VCRG48 Sécurité Votre Pour Important Sécurité Votre PourDES Entretien ET Emploi Installation EmplacementDéballage Roulettes Avec Supports SUR Montées Chauffantes Plaques ’INSTALLATION Normes ET CodesGAZ DU Pression DE Régulateur DU Installation GAZ EN Dalimentation Système DU ÉvaluationConduits DES Connexions Orifice PilotPropane GAZ DU Conversion Utilisation Première LA Avant CommandesEmploi Chauffante Plaque LA DE RodageCoupe DE VUE Cuisson DE Zones ProduitSemaine PAR Fois UNE Utilisation Chaque AprèsChauffante Plaque LA Nettoyage Calibrage RéglagesNiveau À Mise ’ALLUMAGE Veilleuse LA DE RéglageProlongée Fermeture EntretienPièces LES ET L’ENTRETIEN SUR Renseignements VentilationDépannage Possibles CausesProblème