INSTALLATION CLEARANCES |
| |
| COMBUSTIBLE CONSTRUCTION | |
Back: | 6” | 0” |
Sides: | 6” | 0” |
INSTALLATION CODES AND STANDARDS |
|
The griddle must be installed in accordance with:
In the United States of America:
1.State and local codes.
2.National Fuel Gas Code,
NOTE: In the Commonwealth of Massachusetts
All gas appliances vented through a ventilation hood or exhaust system equipped with a damper or with a power means of exhaust shall comply with 248 CMR.
3.NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
In Canada:
1.Local codes.
2.
3.
GRIDDLES MOUNTED ON STANDS WITH CASTERS |
|
Griddles mounted on stands with casters must use a |
|
flexible connector (not supplied) that complies with the |
|
Standard for Connectors for Movable Gas Appliances |
|
ANSI Z21.69•CSA6.16, and a |
|
that complies with Gas Fuel, ANSI Z21.3•CSA6.9. In |
|
addition, adequate means must be provided to limit |
|
movement of the appliance without depending on the |
|
connector and the |
|
associated piping) to limit appliance movement. Attach |
|
the restraining device at the rear of the griddle as |
|
shown in Fig. 1. | Fig. 1 |
If disconnection of the restraint is necessary, turn off the gas supply before disconnecting. Reconnect the restraint prior to turning the gas supply on and returning the griddle to its installation position.
Casters are only supplied on a griddle stand. If the griddle is moved for any reason the griddle should be
- 4 -