Vulcan-Hart VCRG24-T operation manual Cutaway View, VCRG-T / WCRG-T Pilot Lighting Procedure

Page 8

VCRG-T / WCRG-T PILOT LIGHTING PROCEDURE

1.Turn the main gas shut-off valve and all thermostats to the OFF position. Wait 5 minutes to allow any gas that may have accumulated in the burner compartment to escape.

2.Turn the main gas shut-off valve ON.

3.Depress and hold the safety valve button while lighting the corresponding pilot. You will have to reach under the front of the unit to light with an outside ignition source(such as a lit taper, etc.) while viewing thru the pilot sight hole.

4.When the gas at the pilot has been burning for about 45 seconds, release the safety valve button.

If the pilot does not remain lit, repeat the operation allowing more time before releasing the button. The amount of time necessary to hold the safety valve button will increase at the initial installation of the unit and if the main gas supply has been turned off for a long period of time. It may be necessary to adjust the pilot valve to increase gas to the pilot. See Fig. 6 on page 12.

5.Repeat steps until all pilots are lit.

6.If after completing steps 1-5 pilot does not light, turn off the main gas shut-off valve and contact an authorized service agency.

PILOT BURNER

PILOT SIGHT HOLE

THERMOSTAT KNOB

SAFETY VALVE BUTTON

7”

CUTAWAY VIEW

- 8 -

Image 8
Contents Models VCRG48-TFor Your Safety Important for Your SafetyLocation InstallationUnpacking Installation Codes and Standards Griddles Mounted on Stands with CastersTesting the GAS Supply System GAS Pressure Regulator InstallationFlue Connections GAS ConnectionsPropane GAS Conversion Operation Before First USESeasoning the Griddle ControlsVCRG-T / WCRG-T Pilot Lighting Procedure Cutaway ViewUsing the Griddle Zone CookingZone ProductCleaning the Griddle After Each USEOnce PER DAY Once PER WeekAdjustments CalibrationPilot Adjustment LevelingMaintenance Possible Causes TroubleshootingProblem VCRG48 Sécurité Votre Pour Sécurité Votre Pour ImportantDéballage DES Entretien ET Emploi InstallationEmplacement ’INSTALLATION Normes ET Codes Roulettes Avec Supports SUR Montées Chauffantes PlaquesConduits DES Connexions GAZ DU Pression DE Régulateur DU InstallationGAZ EN Dalimentation Système DU Évaluation Propane GAZ DU Conversion OrificePilot Commandes EmploiChauffante Plaque LA DE Rodage Utilisation Première LA AvantCoupe DE VUE Produit Cuisson DE ZonesChauffante Plaque LA Nettoyage Semaine PAR Fois UNEUtilisation Chaque Après Réglages Calibrage’ALLUMAGE Veilleuse LA DE Réglage Niveau À MiseEntretien Pièces LES ET L’ENTRETIEN SUR RenseignementsVentilation Prolongée FermetureProblème DépannagePossibles Causes