Scotsman Ice NME654, NME454, FME804, FME504 manual Auger Maintenance

Page 21

NME454, 654 & FME504, 804

AUGER MAINTENANCE

In some areas, the water supply to the ice maker will contain a high concentration of minerals, and that will result in an evaporator and auger becoming coated with these minerals, requiring a more frequent removal than twice per year. If in doubt about the condition of the evaporator and auger, the auger can be removed so the parts can be inspected.

Note: Water filters can filter out suspended solids, but not dissolved solids. “Soft” water may not be the complete answer. Check with a water treatment specialist regarding water treatment. For more information on removal of these parts, see REMOVAL AND REPLACEMENT.

1.To remove the auger, remove the front and top panels.

2.Push bail clamp back from the top of the chute cover.

3.Unscrew and remove ice sweep.

ICE SWEEP

BREAKER

COVER

FME Components

Shown, NME similar.

4.Remove 4 allen screws holding breaker to evaporator.

5.Pull up to remove auger.

After the auger has been removed, allow the auger to dry: if the auger is not bright and shiny, it must be cleaned.

Clean the auger and evaporator as required. DO NOT HONE THE EVAPORATOR.

FME Components

Shown, NME similar.ALLEN SCREWS

BREAKER &

BEARING &

AUGER

ASSEMBLY

7.Replace the water seal.

8.Reverse to reassemble.

January 2007

Page 21

Image 21
Contents Introduction NME454, 654 & FME504Installation Limitations For the InstallerNME654 Dispenser Applications Fuse Charge Ampacity Size 404ASample BIN and Machine Combinations Water Limitations LocationAirflow Notice For the Installer LocationUse only ¾ rigid tubing For the PlumberFor the Electrician Final Check List Initial Start UP There are no Adjustments to MAKE, so replace the panelsComponent Description Low Pressure Cut Out SwitchNME454, 654 & FME504 On/Off mode Switch Manual control for Control BOX ComponentsAutoSentry Control Board Start Up Electrical SequenceShut Down Control Board Protection DevicesWater Level The correct water level should be Operation WaterOperation Refrigeration Refrigeration SchematicOperation Performance Cleaning & Sanitizing ICE Making System In place cleaningSanitizing Sensor Maintenance AIR Cooled Maintenance Clean the air cooled condenserHazardous Moving Parts Bearing Maintenance OffAt least two times per year Auger Maintenance Symptom Possible Cause Probable Correction Service DiagnosisSymptom Possible Cause Probable Correction Control System Diagnostics BIN Controls Ice Level Sensors Removal and Replacement Bin ControlsTo Remove the Breaker Bearing Assembly Removal and Replacement Bearing And BreakerTo Remove the Auger Removal and Replacement AugerAuger is Stuck,Removal and Replacement Water Seal To Remove the Water SealTo Replace the Water Seal Removal and Replacement Evaporator Heat sink the TXV body when unsweating orResweating the adjacent tubing Removal and Replacement Gear Reducer and Motor Refrigeration System Service Access Valves To useInstructions for Liquid Charging R-404A If the machine is off, not making ice What to do Before Calling for Service