NME454, 654 & FME504, 804
FOR THE INSTALLER
Final Check List
1.Is the ice system installed indoors in a location where the air and water temperatures are controlled, and where they do not exceed the design limitations?
2.Is there an electrical service disconnect within sight of the installed machine? Has the voltage been checked, and compared to nameplate requirements?
3.Have all the plumbing connections been made and checked for leaks?
4.Has the machine and bin been leveled?
5.Is there a minimum of 6" clearance at the back of the machine for proper service access and air circulation?
6.Is the water pressure a minimum of 20 PSIG?
7.Has the machine been secured to the bin?
8.Is there clearance over the top of the machine for service access?
9.Is there a water shut off valve installed near the machine?
10.Have all of the shipping blocks been removed?
January 2007