Scotsman Ice FME504, NME454, NME654, FME804 manual Symptom Possible Cause Probable Correction

Page 23

NME454, 654 & FME504, 804

SERVICE DIAGNOSIS

Symptom

Possible Cause

Probable Correction

 

 

 

Water Leak

Drain plugged up

Clean out drain

 

 

 

 

Tubing cracked

Replace tubing

 

 

 

 

Condensation on drain tubing

Insulate tubing

 

 

 

 

Hose off

Reattach hose

 

 

 

 

Reservoir cover off

Return cover to reservoir

 

 

 

 

Reservoir cracked

Replace reservoir

 

 

 

 

Evaporator water seal leaks

Check base of evaporator & drip pan.

 

 

If the seal leaks, shut off the water,

 

 

remove the auger, replace the water

 

 

seal. Check gear motor for water

 

 

infiltration.

 

 

 

Excessive water use

Water cooled model, water regulating

Adjust to 245 PSIG discharge

 

valve not adjusted properly.

pressure

 

 

 

 

Reservoir float valve leaks thru

Replace float valve or seat

 

 

 

 

Water cooled model, overcharged

Recover and weigh refrigerant. Weigh

 

with refrigerant

in correct charge.

 

 

 

 

Water cooled model, condenser

Acid clean water cooled condenser.

 

coated with minerals

 

 

 

 

Excessive ice meltage

Bin drain clogged

Clean out bin drain.

 

 

 

 

Improper installation of drains, they

Drains must be separate.

 

are connected.

 

 

 

 

 

Poor fit between bin door and door

Adjust or replace

 

frame

 

 

 

 

Machine makes too much noise

Evaporator coated internally with

Clean with Scotsman Ice Machine

 

minerals

Cleaner

 

 

 

 

Motor bearings dry

Oil or replace motor

 

 

 

 

 

 

January 2007

Page 23

Image 23
Contents Introduction NME454, 654 & FME504Fuse Charge Ampacity Size 404A For the InstallerInstallation Limitations NME654 Dispenser ApplicationsSample BIN and Machine Combinations Water Limitations LocationAirflow Notice For the Installer LocationUse only ¾ rigid tubing For the PlumberFor the Electrician Final Check List Initial Start UP There are no Adjustments to MAKE, so replace the panelsComponent Description Low Pressure Cut Out SwitchNME454, 654 & FME504 AutoSentry Control Board On/Off mode Switch Manual control forControl BOX Components Control Board Protection Devices Electrical SequenceStart Up Shut DownWater Level The correct water level should be Operation WaterOperation Refrigeration Refrigeration SchematicOperation Performance Sanitizing Cleaning & SanitizingICE Making System In place cleaning Sensor Maintenance Hazardous Moving Parts AIR Cooled MaintenanceClean the air cooled condenser At least two times per year Bearing Maintenance Off Auger Maintenance Symptom Possible Cause Probable Correction Service DiagnosisSymptom Possible Cause Probable Correction Control System Diagnostics BIN Controls Ice Level Sensors Removal and Replacement Bin ControlsTo Remove the Breaker Bearing Assembly Removal and Replacement Bearing And BreakerStuck, Removal and Replacement AugerTo Remove the Auger Auger isTo Replace the Water Seal Removal and Replacement Water SealTo Remove the Water Seal Resweating the adjacent tubing Removal and Replacement EvaporatorHeat sink the TXV body when unsweating or Removal and Replacement Gear Reducer and Motor Instructions for Liquid Charging R-404A Refrigeration System ServiceAccess Valves To use If the machine is off, not making ice What to do Before Calling for Service