NME454, 654 & FME504, 804
SERVICE DIAGNOSIS
Symptom | Possible Cause | Probable Correction |
|
|
|
Water Leak | Drain plugged up | Clean out drain |
|
|
|
| Tubing cracked | Replace tubing |
|
|
|
| Condensation on drain tubing | Insulate tubing |
|
|
|
| Hose off | Reattach hose |
|
|
|
| Reservoir cover off | Return cover to reservoir |
|
|
|
| Reservoir cracked | Replace reservoir |
|
|
|
| Evaporator water seal leaks | Check base of evaporator & drip pan. |
|
| If the seal leaks, shut off the water, |
|
| remove the auger, replace the water |
|
| seal. Check gear motor for water |
|
| infiltration. |
|
|
|
Excessive water use | Water cooled model, water regulating | Adjust to 245 PSIG discharge |
| valve not adjusted properly. | pressure |
|
|
|
| Reservoir float valve leaks thru | Replace float valve or seat |
|
|
|
| Water cooled model, overcharged | Recover and weigh refrigerant. Weigh |
| with refrigerant | in correct charge. |
|
|
|
| Water cooled model, condenser | Acid clean water cooled condenser. |
| coated with minerals |
|
|
|
|
Excessive ice meltage | Bin drain clogged | Clean out bin drain. |
|
|
|
| Improper installation of drains, they | Drains must be separate. |
| are connected. |
|
|
|
|
| Poor fit between bin door and door | Adjust or replace |
| frame |
|
|
|
|
Machine makes too much noise | Evaporator coated internally with | Clean with Scotsman Ice Machine |
| minerals | Cleaner |
|
|
|
| Motor bearings dry | Oil or replace motor |
|
|
|
|
|
|
January 2007