Vulcan-Hart VSX5GC, VSX7GC, VSX10GC operation manual Installation Codes and Standards, Location

Page 5

INSTALLATION CODES AND STANDARDS

In the United States, the steamer must be installed in accordance with:

1.State and local codes.

2.National Fuel Gas Code, ANSI-Z223.1 (latest edition), available from the American Gas Association, 1515 Wilson Boulevard, Arlington, VA 22209.

3.National Electrical Code, ANSI/NFPA No. 70 (latest edition), available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

4.NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

In Canada, the steamer must be installed in accordance with:

1.Local codes.

2.Natural Gas and Propane Installation Code CSA B149.1 (latest edition).

LOCATION

Before installing, verify that the gas (natural or propane) and the electrical supply agree with the specifications on the data plate.

The installation location must be kept free and clear of combustibles. Do not obstruct the flow of combustion and ventilation air. Minimum clearances from noncombustible and combustible construction are 8 inches (20 cm) on the right side, 3 inches (8 cm) on the left side, and 6 inches (15 cm) at the rear for proper air circulation. The steamer should be installed on a noncombustible floor. Provide adequate clearances for cleaning, maintenance, service and proper operation.

Sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system and for combustion of the gas burners. Do not obstruct the air flow into and around the appliance. Do not obstruct the flow of flue gases from the flue duct located at the rear and above the steamer. Position the steamer in its final location. Check that there are sufficient clearances to service the controls, for door(s) to swing and to allow the required supply and drain connections.

Allow enough space between any other piece of equipment or a wall for service access. Service for the controls for the steamer compartments requires access to the upper right side panel.

LEGS (Countertop Steamer—Model VSX5G only)

Install 4" legs by threading the stud into the holes provided underneath at four corners.

– 5 –

Image 5
Contents Models VSX 5G For Your Safety Important for Your SafetyTable of Contents General InstallationAccommodation and Gas Rating UnpackingLegs Countertop Steamer-Model VSX5G only Installation Codes and StandardsLocation Plumbing Connections LevelingVent Hood Drain Connections Testing the GAS Supply PipingDraining Requirements GAS ConnectionElectrical Data Electrical ConnectionTest Procedure Controls Main Power SwitchOperation Daily Shutdown Procedure Startup ProcedureProcedure for Complete or Prolonged Shutdown Stand byCompartment Accommodation Steam CookingPreparation Cleaning Weekly More Often if Needed Service and Parts Information MaintenanceDeliming Steam Unloader PortsSymptom Possible Cause Troubleshooting

VSX10GC, VSX7GC, VSX5G, VSX5GC specifications

The Vulcan-Hart line of products, including the VSX5GC, VSX5G, VSX7GC, and VSX10GC, represents a pinnacle in commercial cooking technology, ideal for restaurants, cafeterias, and various foodservice operations. Each model brings unique features and specifications tailored to meet diverse culinary requirements while ensuring efficiency and durability.

The VSX5GC stands out with its compact design, making it suitable for establishments with limited kitchen space. This gas-powered unit includes five burners, providing exceptional heat control for sautéing, boiling, and simmering. With a robust stainless steel construction, it promises longevity and easy maintenance. Its efficiency is further amplified by the inclusion of cast iron grates, which offer excellent heat retention and distribution. This model represents an excellent choice for small to mid-sized operations seeking reliability without sacrificing performance.

The VSX5G is a versatile counterpart to the VSX5GC, featuring identical burner configurations and construction quality. However, it boasts a slightly enhanced design that prioritizes ease of use. The VSX5G incorporates ergonomic knobs and intuitive controls, allowing chefs to adjust temperatures seamlessly under pressure. This unit is suited for both business establishments and high-demand kitchens that require swift transitions without compromising food quality.

Moving to the VSX7GC, this more powerful model features seven burners, catering to larger foodservice operations. The additional burner capacity enhances cooking versatility, allowing chefs to prepare multiple dishes simultaneously. It retains the rugged stainless steel finish and cast iron grates. An additional benefit of the VSX7GC is its upgraded ignition system, which facilitates quicker and more reliable starts—an essential feature during peak service times.

Lastly, the VSX10GC is the flagship model, designed for high-volume kitchens that demand maximum efficiency and output. With ten burners, this heavy-duty unit can handle various cooking techniques at once. Its robust construction, integrated with advanced gas control technology, ensures precise temperature management—a critical aspect in creating consistent culinary masterpieces. Furthermore, the VSX10GC showcases a wider cooking surface, allowing for larger pots and pans, thus expediting meal preparation.

Overall, the Vulcan-Hart lineup—comprising the VSX5GC, VSX5G, VSX7GC, and VSX10GC—offers unmatched performance, durability, and flexibility. Each model is engineered to accommodate different scales of operations, ensuring that every commercial kitchen can find the right fit for its culinary needs. With advanced technology and robust construction at their core, Vulcan-Hart cooking equipment stands as a trusted choice among industry professionals, fostering a foundation for culinary excellence.