Vulcan-Hart C24GA6 ML-136021, C24GA10 ML-136022 service manual Automatic Ignition Systems

Page 17

C24GA SERIES CONVECTION STEAMERS - SERVICE PROCEDURES AND ADJUSTMENTS

AUTOMATIC IGNITION SYSTEMS

When the main power switch is turned on and the water level is above LLCO, the ignition control module is energized with 24 volts between terminals five and six. High voltage is sent from terminal nine to the spark electrode and an output of 24 volts is sent from terminals two and three to the pilot coil in the combi- nation valve, allowing gas to flow to the pilot. The sparking will continue for 90 seconds or until the flame sensor has confirmed that an adequate pilot flame is present.

Once the pilot flame is confirmed, a 24 volt output from terminal one will be sent to the gas combination control valve.

TERMINAL

DESCRIPTION

NO.

1

Voltage (24 VAC) will be present on MV

 

terminal #1 with the pilot sensing

 

electrode sensing an adequate pilot

 

flame. This output will remain present

 

as long as the pilot flame remains

 

adequate.

2

Common MV/PV.

3

The Pilot Voltage (24 VAC) will be

 

present on terminal #3 at the instant

 

an input voltage is supplied to the

 

module. This voltage will remain

 

present on terminal #3 providing an

 

adequate pilot flame is established

 

within 90 seconds. In the event that an

 

adequate pilot flame is not established

 

within 90 seconds this output voltage

 

will drop out.

4

Ground (burner).

5

Ground (24 VAC Neutral).

6

24 VAC Input.

8

Flame Sensor.

9

High Voltage to spark electrode.

 

 

Spark Ignition Control Test

The ignition control module and ignition control module transformer are located in the electronics enclosure behind the generator base front cover.

1.Check for earth ground.

2.Check to ensure that all electrical terminal connections on the ignition control module and the igniter are clean and tight.

3.Verify that the ignition control module and the igniter have good ground wire connections. The igniter mounting bracket should have good metal to metal contact to its mounting surface.

4.Turn the main power switch on. Make sure LLCO light is on.

5.Check for 24VAC output on the ignition control module transformer.

Page 17 of 40

 

F35425 (February 2006)

 

Image 17
Contents Steamers ConvectionTable of Contents Low Level Cut-Off & Differential Control General Installation Operation Cleaning SpecificationsIntroduction ToolsCovers and Panels Removal and Replacement of PartsCooking Compartment Door Door AssemblyCabinet Base Left Side Panel Cabinet Base Rear PanelDoor Handle Door GasketCompartment Controls Door Latch AssemblyGAS Combination Control Valve Generator AssemblyMain Burner Covers and Panels Fill and Cold Water Solenoid Valves PILOT/SPARK Probe Flame Sensor Blower AIR Pressure Adjustment AIR Pressure Switch Service Procedures and AdjustmentsPilot Burner Adjustment Operating Pressure Switch Thumb Wheel Adjustment Inlet Water/Steam Strainer Spark Ignition Control Test Automatic Ignition SystemsIgnition Test Manifold Pressure AdjustmentControls Latch AdjustmentCooking Compartment Deliming the Generator Striker AdjustmentItems Required not provided C24GA Automatic Drain US GAL Capacity Steam GeneratorGeneral Cooking Cycle TestProbe Inspection Water Level Controls Electrical OperationSequence of Operation Low Level Cut-Off and Differential ControlC24GA Series Convection Steamers Electrical Operation Compartment control Units after Dec Generator Schematic Diagram Schematic DiagramsSchematic Diagram Compartment Controls Standard Schematic Diagram Compartment Controls Constant Steam Component Location Cabinet Base Generator Component Function Cabinet Base Generator Super Heater Assembly Blower Air Pressure SwitchDrain Valve Timer Hold ThermostatComponent Location Cooking Compartment Component Function Cooking Compartment Troubleshooting Step Function Description Troubleshooting Sequence of OperationSymptom Possible Causes Troubleshooting ChartSymptom Possible Causes Symptom Possible Causes Condensed Spare Parts List F35425 February

C24GA6 ML-136021, C24GA10 ML-136022, C24GA6, C24GA10, ML-136021, ML-136022 specifications

The Vulcan-Hart C24GA series is renowned in the commercial kitchen industry for its high-quality performance and efficient cooking capabilities. This series includes models C24GA6 and C24GA10, which are designed with versatility and reliability at their core. These models cater to a wide range of culinary demands, ensuring that chefs can prepare a variety of dishes with ease.

The C24GA6 features six powerful burners, providing ample cooking space and heat output for busy kitchens. Its robust construction ensures durability, while an easy-to-clean stainless steel exterior makes maintenance hassle-free. The burners are designed for quick ignition, and the adjustable flame control allows for precise temperature adjustments, ideal for simmering sauces or achieving the perfect sear.

On the other hand, the C24GA10 model is equipped with ten burners, making it suitable for larger establishments that require additional cooking power. Similar to the C24GA6, it incorporates seamless stainless steel components and a design that meets the rigorous demands of a professional kitchen. Both models boast a high BTU output, ensuring that meals are prepared quickly and efficiently, which is essential during peak hours.

The C24GA series also integrates advanced technologies that enhance its functionality. The burners utilize a standing pilot ignition system, ensuring a reliable start-up every time. This technology minimizes downtime and allows chefs to focus on cooking rather than troubleshooting equipment.

In addition to the C24GA series, Vulcan-Hart offers the ML-136021 and ML-136022 models, which complement the cooking arsenal in any kitchen. These models are expertly designed to provide the same level of reliability and performance. They follow the same principles of durability and ease of maintenance that Vulcan-Hart is known for.

The ML-136021 and ML-136022 models feature streamlined designs that fit seamlessly into any workspace. With efficient heat distribution and user-friendly controls, these models are perfect for both experienced chefs and culinary students alike.

Together, the Vulcan-Hart C24GA6, C24GA10, ML-136021, and ML-136022 models represent a comprehensive cooking solution that meets the varied needs of commercial kitchens. With their powerful burners, durable construction, and advanced technologies, these units ensure top-notch performance and efficiency for all cooking requirements.