C24GA SERIES CONVECTION STEAMERS - SERVICE PROCEDURES AND ADJUSTMENTS

SERVICE PROCEDURES AND ADJUSTMENTS

WARNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRE ELECTRICAL TEST OR MEASURE- MENTS WHILE POWER IS APPLIED TO THE MACHINE. EXERCISE EXTREME CAUTION AT ALL TIMES. IF TEST POINTS ARE NOT EASILY ACCESSIBLE, DISCONNECT POWER AND FOLLOW LOCKOUT / TAGOUT PROCEDURES, ATTACH TEST EQUIPMENT AND REAPPLY POWER TO TEST.

BLOWER AIR PRESSURE

ADJUSTMENT

AIR PRESSURE SWITCH

ADJUSTMENT

Adjust the blower air pressure at the gas combination manifold pressure tap. Turn the gas valve off. Remove pipe plug from pressure tap on the outlet side of the gas combination valve and install a gas manometer. The air pressure should be 0.35"W.C. (0.09 kPa) to 0.4"W.C. (1 kPa). If the reading is not correct adjust blower speed control adjustment screw clockwise to increase and counter-clockwise to decrease.

Blower air pressure adjustment must be performed before proceeding with this procedure.

The air pressure switch senses the pressure level produced by the blower for combustion. When the pressure is sufficient, the switch closes and supplies power to the ignition control module. The gas ignition sequence starts to light the gas pilot and then main burner. If gas pilot is not lighting (valve not energized), the ignition control module may not be receiving power, assuming the minimum water level is satisfied. Check the air pressure switch operation then adjust if necessary as outlined in the procedure below.

1.Turn the power switch off.

2.Remove the front panel from the cabinet base.

A.Inspect the air intake to the blower for debris build up and clogging.

1)If debris is found, clean it away from the air intake.

B.Turn the power switch on and verify main burner ignition.

1)If burner ignites no adjustment to the pressure switch setting is necessary.

2)If burner does not ignite, proceed to step 3.

3.Turn the main gas valve to off.

4.Adjust the air pressure switch setting as follows:

A.Turn the adjustment screw fully clockwise to the highest setting.

B.Slowly turn the adjustment screw counter- clockwise until main gas valve energizes then add 1/2 turn to the adjustment.

Page 13 of 40

 

F35425 (February 2006)

 

Image 13
Contents Steamers ConvectionTable of Contents Low Level Cut-Off & Differential Control General Installation Operation Cleaning SpecificationsIntroduction ToolsCovers and Panels Removal and Replacement of PartsCooking Compartment Door Door AssemblyCabinet Base Left Side Panel Cabinet Base Rear PanelDoor Handle Door GasketCompartment Controls Door Latch AssemblyMain Burner Generator AssemblyGAS Combination Control Valve Covers and Panels Fill and Cold Water Solenoid Valves PILOT/SPARK Probe Flame Sensor Blower AIR Pressure Adjustment AIR Pressure Switch Service Procedures and AdjustmentsPilot Burner Adjustment Operating Pressure Switch Thumb Wheel Adjustment Inlet Water/Steam Strainer Spark Ignition Control Test Automatic Ignition SystemsIgnition Test Manifold Pressure AdjustmentCooking Compartment Latch AdjustmentControls Deliming the Generator Striker AdjustmentItems Required not provided C24GA Automatic Drain US GAL Capacity Steam GeneratorProbe Inspection Cooking Cycle TestGeneral Water Level Controls Electrical OperationSequence of Operation Low Level Cut-Off and Differential ControlC24GA Series Convection Steamers Electrical Operation Compartment control Units after Dec Generator Schematic Diagram Schematic DiagramsSchematic Diagram Compartment Controls Standard Schematic Diagram Compartment Controls Constant Steam Component Location Cabinet Base Generator Component Function Cabinet Base Generator Super Heater Assembly Blower Air Pressure SwitchDrain Valve Timer Hold ThermostatComponent Location Cooking Compartment Component Function Cooking Compartment Troubleshooting Step Function Description Troubleshooting Sequence of OperationSymptom Possible Causes Troubleshooting ChartSymptom Possible Causes Symptom Possible Causes Condensed Spare Parts List F35425 February

C24GA6 ML-136021, C24GA10 ML-136022, C24GA6, C24GA10, ML-136021, ML-136022 specifications

The Vulcan-Hart C24GA series is renowned in the commercial kitchen industry for its high-quality performance and efficient cooking capabilities. This series includes models C24GA6 and C24GA10, which are designed with versatility and reliability at their core. These models cater to a wide range of culinary demands, ensuring that chefs can prepare a variety of dishes with ease.

The C24GA6 features six powerful burners, providing ample cooking space and heat output for busy kitchens. Its robust construction ensures durability, while an easy-to-clean stainless steel exterior makes maintenance hassle-free. The burners are designed for quick ignition, and the adjustable flame control allows for precise temperature adjustments, ideal for simmering sauces or achieving the perfect sear.

On the other hand, the C24GA10 model is equipped with ten burners, making it suitable for larger establishments that require additional cooking power. Similar to the C24GA6, it incorporates seamless stainless steel components and a design that meets the rigorous demands of a professional kitchen. Both models boast a high BTU output, ensuring that meals are prepared quickly and efficiently, which is essential during peak hours.

The C24GA series also integrates advanced technologies that enhance its functionality. The burners utilize a standing pilot ignition system, ensuring a reliable start-up every time. This technology minimizes downtime and allows chefs to focus on cooking rather than troubleshooting equipment.

In addition to the C24GA series, Vulcan-Hart offers the ML-136021 and ML-136022 models, which complement the cooking arsenal in any kitchen. These models are expertly designed to provide the same level of reliability and performance. They follow the same principles of durability and ease of maintenance that Vulcan-Hart is known for.

The ML-136021 and ML-136022 models feature streamlined designs that fit seamlessly into any workspace. With efficient heat distribution and user-friendly controls, these models are perfect for both experienced chefs and culinary students alike.

Together, the Vulcan-Hart C24GA6, C24GA10, ML-136021, and ML-136022 models represent a comprehensive cooking solution that meets the varied needs of commercial kitchens. With their powerful burners, durable construction, and advanced technologies, these units ensure top-notch performance and efficiency for all cooking requirements.