Vulcan-Hart C24GA6 ML-136021, C24GA10 ML-136022 Main Burner, GAS Combination Control Valve

Page 9

C24GA SERIES CONVECTION STEAMERS - REMOVALAND REPLACEMENT OF PARTS

MAIN BURNER

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

1.Remove front and side covers as outlined under

COVERS AND PANELS.

2.Disconnect the gas line at gas combination control valve.

3.Disconnect wires to burner assembly.

4.Remove the nuts securing burner to tank.

5.Drop blower end of burner assembly slightly down to clear control box and push all interfering wires out of the way so that burner can be pulled out of tank.

6.Reverse procedure to install burner assembly.

GAS COMBINATION

CONTROL VALVE

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

WARNING: SHUT OFF THE GAS SUPPLY BEFORE SERVICING THE UNIT.

WARNING: ALL GAS JOINTS DISTURBED DURING SERVICING MUST BE CHECKED FOR LEAKS. CHECK WITH A SOAP AND WATER SOLUTION (BUBBLES). DO NOT USE AN OPEN FLAME.

A.CHECK ALL JOINTS PRIOR TO THE GAS VALVE (SOLENOID) BEFORE LIGHTING THE UNIT.

B.CHECK ALL JOINTS BEYOND GAS VALVE (SOLENOID) AFTER UNIT IS LIT.

Gas combination control valves are not serviceable and should not be disassembled. Once the problem has been isolated to this control, replace it. Do not attempt to repair the assembly.

1.Remove the front and right side panels as outlined under COVERS AND PANELS.

2.Remove main burner as outlined in MAIN BURNER.

3.Disconnect electrical supply wires running to the gas combination control valve.

4.Disconnect the pilot gas supply tube from the control and pipe connections on each side of the gas combination control valve.

5.Reverse procedure to install and check unit for proper operation.

GENERATOR ASSEMBLY

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

WARNING: SHUT OFF THE GAS SUPPLY BEFORE SERVICING THE UNIT.

WARNING: ALL GAS JOINTS DISTURBED DURING SERVICING MUST BE CHECKED FOR LEAKS. CHECK WITH A SOAP AND WATER SOLUTION (BUBBLES). DO NOT USE AN OPEN FLAME.

A.CHECK ALL JOINTS PRIOR TO THE GAS VALVE (SOLENOID) BEFORE LIGHTING THE UNIT.

B.CHECK ALL JOINTS BEYOND GAS VALVE (SOLENOID) AFTER UNIT IS LIT.

Page 9 of 40

 

F35425 (February 2006)

 

Image 9
Contents Steamers ConvectionTable of Contents Low Level Cut-Off & Differential Control General Installation Operation Cleaning SpecificationsIntroduction ToolsCovers and Panels Removal and Replacement of PartsCooking Compartment Door Door AssemblyCabinet Base Left Side Panel Cabinet Base Rear PanelDoor Handle Door GasketCompartment Controls Door Latch AssemblyGenerator Assembly Main BurnerGAS Combination Control Valve Covers and Panels Fill and Cold Water Solenoid Valves PILOT/SPARK Probe Flame Sensor Blower AIR Pressure Adjustment AIR Pressure Switch Service Procedures and AdjustmentsPilot Burner Adjustment Operating Pressure Switch Thumb Wheel Adjustment Inlet Water/Steam Strainer Spark Ignition Control Test Automatic Ignition SystemsIgnition Test Manifold Pressure AdjustmentLatch Adjustment Cooking CompartmentControls Deliming the Generator Striker AdjustmentItems Required not provided C24GA Automatic Drain US GAL Capacity Steam GeneratorCooking Cycle Test Probe InspectionGeneral Water Level Controls Electrical OperationSequence of Operation Low Level Cut-Off and Differential ControlC24GA Series Convection Steamers Electrical Operation Compartment control Units after Dec Generator Schematic Diagram Schematic DiagramsSchematic Diagram Compartment Controls Standard Schematic Diagram Compartment Controls Constant Steam Component Location Cabinet Base Generator Component Function Cabinet Base Generator Super Heater Assembly Blower Air Pressure SwitchDrain Valve Timer Hold ThermostatComponent Location Cooking Compartment Component Function Cooking Compartment Troubleshooting Step Function Description Troubleshooting Sequence of OperationSymptom Possible Causes Troubleshooting ChartSymptom Possible Causes Symptom Possible Causes Condensed Spare Parts List F35425 February

C24GA6 ML-136021, C24GA10 ML-136022, C24GA6, C24GA10, ML-136021, ML-136022 specifications

The Vulcan-Hart C24GA series is renowned in the commercial kitchen industry for its high-quality performance and efficient cooking capabilities. This series includes models C24GA6 and C24GA10, which are designed with versatility and reliability at their core. These models cater to a wide range of culinary demands, ensuring that chefs can prepare a variety of dishes with ease.

The C24GA6 features six powerful burners, providing ample cooking space and heat output for busy kitchens. Its robust construction ensures durability, while an easy-to-clean stainless steel exterior makes maintenance hassle-free. The burners are designed for quick ignition, and the adjustable flame control allows for precise temperature adjustments, ideal for simmering sauces or achieving the perfect sear.

On the other hand, the C24GA10 model is equipped with ten burners, making it suitable for larger establishments that require additional cooking power. Similar to the C24GA6, it incorporates seamless stainless steel components and a design that meets the rigorous demands of a professional kitchen. Both models boast a high BTU output, ensuring that meals are prepared quickly and efficiently, which is essential during peak hours.

The C24GA series also integrates advanced technologies that enhance its functionality. The burners utilize a standing pilot ignition system, ensuring a reliable start-up every time. This technology minimizes downtime and allows chefs to focus on cooking rather than troubleshooting equipment.

In addition to the C24GA series, Vulcan-Hart offers the ML-136021 and ML-136022 models, which complement the cooking arsenal in any kitchen. These models are expertly designed to provide the same level of reliability and performance. They follow the same principles of durability and ease of maintenance that Vulcan-Hart is known for.

The ML-136021 and ML-136022 models feature streamlined designs that fit seamlessly into any workspace. With efficient heat distribution and user-friendly controls, these models are perfect for both experienced chefs and culinary students alike.

Together, the Vulcan-Hart C24GA6, C24GA10, ML-136021, and ML-136022 models represent a comprehensive cooking solution that meets the varied needs of commercial kitchens. With their powerful burners, durable construction, and advanced technologies, these units ensure top-notch performance and efficiency for all cooking requirements.