Vulcan-Hart C24GA6 ML-136021, C24GA10 ML-136022 Component Function Cabinet Base Generator

Page 29

C24GA SERIES CONVECTION STEAMERS - ELECTRICAL OPERATION

COMPONENT FUNCTION

CABINET BASE GENERATOR

Water Level Control and

 

Level Sensing Probes

The Water Level Control circuit board and Level Sensing Probe Assembly

 

allow water to enter the generator to fill and maintain the proper water level.

 

These probes will also shut off the heat source to the generator if the water

 

level drops too low.

 

The water level control works by using three different probe lengths to monitor

 

the water level. The probes consist of a high level (HL), low level (LL), and low

 

water cut-off (LLCO) probe. The level sensing probes may easily be removed to

 

inspect for lime build up. As a rule, the condition of these devices will indicate

 

the overall water condition of the generator. Clean the probes, if necessary.

Generator Fast Fill

 

Solenoid Valve

The Generator Fast Fill Solenoid Valve is located on the right side of the

 

base and admits water at rate of 3.7 GPM to the generator when demanded by

 

the water level control to maintain the correct water level in the generator.

Generator Slow Fill

 

Solenoid Valve

The Generator Slow (Trickle) Fill Solenoid Valve is located on the right side of

 

the base and admits water to the generator at a rate of 0.25 GPM when

 

demanded by the water level control to maintain the correct water level in the

 

generator.

 

The output of the Fast Fill and Slow Fill valves are connected in a “Y” to provide

 

a single feed to the generator.

Cold Water Condenser (CWC)

 

Solenoid Valve

The Cold Water Condenser (CWC) Solenoid Valve allows cold water to flow

 

into the generator drain to condense steam and cool the hot water before it is

 

discharged into the drain.

Cavity Cold Water

 

Solenoid Valve

The Cavity Cold Water Solenoid Valve allows cold water to flow into the

 

cavity drain and cool the hot water before it is discharged into the drain.

Operating Pressure Switch

The Pressure Switch is located on the front upper right corner of the

 

generator and is accessible through the left side panel. This switch controls

 

generator pressure between prescribed limits by turning the heat source on

 

and off.

Drain Solenoid Valve

The Drain Solenoid Valve (Drain Valve) is located on the right side of the base

 

and is plumbed into the drain pipe of the generator. The generator will

 

automatically drain for 1000 seconds when power is turned off by using a

 

normally closed solenoid valve. Daily generator draining is essential to proper

 

operation and component life by removing sediment and scalants that may be

 

lodged in the chamber of the generator.

Strainers

Strainers are used in the water inlet line to prevent foreign matter from

 

becoming lodged in the fill or cold water condenser solenoid valves and to keep

 

unwanted particles out of the system. Strainers are also located in the steam

 

line and drain line.

Pressure Gauge

 

(If applicable)

The Pressure Gauge is located on the upper right front of the base and indi-

 

cates generator steam pressure.

Cold Water Thermostat

The Cold Water Thermostat is located on the lower right side of the base and

 

maintains drain temperature below 140°F by controlling the drain CWC

 

solenoid.

Page 29 of 40

 

F35425 (February 2006)

 

Image 29
Contents Steamers ConvectionTable of Contents Low Level Cut-Off & Differential Control General Installation Operation Cleaning SpecificationsIntroduction ToolsCovers and Panels Removal and Replacement of PartsCooking Compartment Door Door AssemblyCabinet Base Left Side Panel Cabinet Base Rear PanelDoor Handle Door GasketCompartment Controls Door Latch AssemblyGAS Combination Control Valve Generator AssemblyMain Burner Covers and Panels Fill and Cold Water Solenoid Valves PILOT/SPARK Probe Flame Sensor Blower AIR Pressure Adjustment AIR Pressure Switch Service Procedures and AdjustmentsPilot Burner Adjustment Operating Pressure Switch Thumb Wheel Adjustment Inlet Water/Steam Strainer Spark Ignition Control Test Automatic Ignition SystemsIgnition Test Manifold Pressure AdjustmentControls Latch AdjustmentCooking Compartment Deliming the Generator Striker AdjustmentItems Required not provided C24GA Automatic Drain US GAL Capacity Steam GeneratorGeneral Cooking Cycle TestProbe Inspection Water Level Controls Electrical OperationSequence of Operation Low Level Cut-Off and Differential ControlC24GA Series Convection Steamers Electrical Operation Compartment control Units after Dec Generator Schematic Diagram Schematic DiagramsSchematic Diagram Compartment Controls Standard Schematic Diagram Compartment Controls Constant Steam Component Location Cabinet Base Generator Component Function Cabinet Base Generator Super Heater Assembly Blower Air Pressure SwitchDrain Valve Timer Hold ThermostatComponent Location Cooking Compartment Component Function Cooking Compartment Troubleshooting Step Function Description Troubleshooting Sequence of OperationSymptom Possible Causes Troubleshooting ChartSymptom Possible Causes Symptom Possible Causes Condensed Spare Parts List F35425 February

C24GA6 ML-136021, C24GA10 ML-136022, C24GA6, C24GA10, ML-136021, ML-136022 specifications

The Vulcan-Hart C24GA series is renowned in the commercial kitchen industry for its high-quality performance and efficient cooking capabilities. This series includes models C24GA6 and C24GA10, which are designed with versatility and reliability at their core. These models cater to a wide range of culinary demands, ensuring that chefs can prepare a variety of dishes with ease.

The C24GA6 features six powerful burners, providing ample cooking space and heat output for busy kitchens. Its robust construction ensures durability, while an easy-to-clean stainless steel exterior makes maintenance hassle-free. The burners are designed for quick ignition, and the adjustable flame control allows for precise temperature adjustments, ideal for simmering sauces or achieving the perfect sear.

On the other hand, the C24GA10 model is equipped with ten burners, making it suitable for larger establishments that require additional cooking power. Similar to the C24GA6, it incorporates seamless stainless steel components and a design that meets the rigorous demands of a professional kitchen. Both models boast a high BTU output, ensuring that meals are prepared quickly and efficiently, which is essential during peak hours.

The C24GA series also integrates advanced technologies that enhance its functionality. The burners utilize a standing pilot ignition system, ensuring a reliable start-up every time. This technology minimizes downtime and allows chefs to focus on cooking rather than troubleshooting equipment.

In addition to the C24GA series, Vulcan-Hart offers the ML-136021 and ML-136022 models, which complement the cooking arsenal in any kitchen. These models are expertly designed to provide the same level of reliability and performance. They follow the same principles of durability and ease of maintenance that Vulcan-Hart is known for.

The ML-136021 and ML-136022 models feature streamlined designs that fit seamlessly into any workspace. With efficient heat distribution and user-friendly controls, these models are perfect for both experienced chefs and culinary students alike.

Together, the Vulcan-Hart C24GA6, C24GA10, ML-136021, and ML-136022 models represent a comprehensive cooking solution that meets the varied needs of commercial kitchens. With their powerful burners, durable construction, and advanced technologies, these units ensure top-notch performance and efficiency for all cooking requirements.