C24GA SERIES CONVECTION STEAMERS - SERVICE PROCEDURES AND ADJUSTMENTS

5.Verify burner air pressure is 0.35" to 0.4" W.C.

6.Turn the gas combination control valve on and wait until main burner lights.

7.Observe the manometer pressure reading and compare to the pressure chart below.

GAS PRESSURE READINGS (INCHES W.C.)

 

MANIFOLD

LINE*

 

 

 

 

 

 

 

GASTYPE

 

RECOMMENDED

MIN

MAX

 

 

 

 

 

Natural

2.5

7.0

5.0

14

 

 

 

 

 

Propane

10.0

11.0

11.0

14

 

 

 

 

 

5.Check wiring for damaged insulation (no short circuit).

6.Check that all connections and terminals are securely fastened (no open circuits).

7.Check that all connections are made according to compartment control wiring diagram.

DOOR

Latch Adjustment

If the cabinet door jams and cannot be opened, do not force or pry the door, as damage will occur.

*If the incoming line pressure is less than the minimum stated, then the manifold pressure cannot be set correctly.

8.Once the correct pressure has been set, turn the power switch and gas supply off, replace the adjustment screw cap and 1/8" NPT plug (pressure tap) on the outlet side of the valve.

First, try lifting up on the bottom of the door at the handle end to disengage the latch. If that does not work, remove the right side panel from the cooking compartment as outlined under COVERS AND PANELS.

The striker that catches on the door latch is located behind the front face of the cooking cavity. Remove the nut from the striker to release it from the panel.

COOKING COMPARTMENT

Controls

1.For access to compartment controls, remove the right side panel from the cooking compartment as outlined under COVERS AND PANELS.

2.Check door switch for proper operation.

3.Check cooking timer function and contact position. See SCHEMATICS under ELECTRICAL OPERATION.

4.Check that timer motor operates when connected to power. If a problem is found in timer, replace it, do not take timer apart.

Once the nut and washer have been removed, door will open freely.

Remove any burrs on the striker that may cause the latch to stick. Reinstall the striker and adjust so door will not jam.

Page 19 of 40

 

F35425 (February 2006)

 

Image 19
Contents Steamers ConvectionTable of Contents Low Level Cut-Off & Differential Control Tools Installation Operation Cleaning SpecificationsGeneral IntroductionCovers and Panels Removal and Replacement of PartsCabinet Base Rear Panel Door AssemblyCooking Compartment Door Cabinet Base Left Side PanelDoor Handle Door GasketCompartment Controls Door Latch AssemblyMain Burner Generator AssemblyGAS Combination Control Valve Covers and Panels Fill and Cold Water Solenoid Valves PILOT/SPARK Probe Flame Sensor Blower AIR Pressure Adjustment AIR Pressure Switch Service Procedures and AdjustmentsPilot Burner Adjustment Operating Pressure Switch Thumb Wheel Adjustment Inlet Water/Steam Strainer Spark Ignition Control Test Automatic Ignition SystemsIgnition Test Manifold Pressure AdjustmentCooking Compartment Latch AdjustmentControls C24GA Automatic Drain US GAL Capacity Steam Generator Striker AdjustmentDeliming the Generator Items Required not providedProbe Inspection Cooking Cycle TestGeneral Low Level Cut-Off and Differential Control Electrical OperationWater Level Controls Sequence of OperationC24GA Series Convection Steamers Electrical Operation Compartment control Units after Dec Generator Schematic Diagram Schematic DiagramsSchematic Diagram Compartment Controls Standard Schematic Diagram Compartment Controls Constant Steam Component Location Cabinet Base Generator Component Function Cabinet Base Generator Hold Thermostat Blower Air Pressure SwitchSuper Heater Assembly Drain Valve TimerComponent Location Cooking Compartment Component Function Cooking Compartment Troubleshooting Step Function Description Troubleshooting Sequence of OperationSymptom Possible Causes Troubleshooting ChartSymptom Possible Causes Symptom Possible Causes Condensed Spare Parts List F35425 February

C24GA6 ML-136021, C24GA10 ML-136022, C24GA6, C24GA10, ML-136021, ML-136022 specifications

The Vulcan-Hart C24GA series is renowned in the commercial kitchen industry for its high-quality performance and efficient cooking capabilities. This series includes models C24GA6 and C24GA10, which are designed with versatility and reliability at their core. These models cater to a wide range of culinary demands, ensuring that chefs can prepare a variety of dishes with ease.

The C24GA6 features six powerful burners, providing ample cooking space and heat output for busy kitchens. Its robust construction ensures durability, while an easy-to-clean stainless steel exterior makes maintenance hassle-free. The burners are designed for quick ignition, and the adjustable flame control allows for precise temperature adjustments, ideal for simmering sauces or achieving the perfect sear.

On the other hand, the C24GA10 model is equipped with ten burners, making it suitable for larger establishments that require additional cooking power. Similar to the C24GA6, it incorporates seamless stainless steel components and a design that meets the rigorous demands of a professional kitchen. Both models boast a high BTU output, ensuring that meals are prepared quickly and efficiently, which is essential during peak hours.

The C24GA series also integrates advanced technologies that enhance its functionality. The burners utilize a standing pilot ignition system, ensuring a reliable start-up every time. This technology minimizes downtime and allows chefs to focus on cooking rather than troubleshooting equipment.

In addition to the C24GA series, Vulcan-Hart offers the ML-136021 and ML-136022 models, which complement the cooking arsenal in any kitchen. These models are expertly designed to provide the same level of reliability and performance. They follow the same principles of durability and ease of maintenance that Vulcan-Hart is known for.

The ML-136021 and ML-136022 models feature streamlined designs that fit seamlessly into any workspace. With efficient heat distribution and user-friendly controls, these models are perfect for both experienced chefs and culinary students alike.

Together, the Vulcan-Hart C24GA6, C24GA10, ML-136021, and ML-136022 models represent a comprehensive cooking solution that meets the varied needs of commercial kitchens. With their powerful burners, durable construction, and advanced technologies, these units ensure top-notch performance and efficiency for all cooking requirements.