Vulcan-Hart C24GA6, C24GA10, ML-136021, ML-136022 Compartment control Units after Dec

Page 24

C24GA SERIES CONVECTION STEAMERS - ELECTRICAL OPERATION

Compartment control (Units after Dec. 1, 2005)

Refer to schematic diagrams 00855693 & 00856656.

1.Compartment door closed causing door switch to close and Ready Light to illuminate.

A.120 VAC applied through door switch to timer contact 11 and 21.

B.Timer manually set to desired time period.

C.Voltage applied through contacts 11 and 13.

1)Timer begins countdown.

2)Voltage applied through contacts 21 and 23.

3)Steam solenoid energized allowing steam into compartment.

4)Cavity relay 1 energized, energizing the CWC solenoid.

5)Cook Light illuminated.

D.Timer times out.

1)Contacts 11 – 13 open and contacts

11 and 14 close energizing the buzzer.

2)Timer contacts 21 – 23 open turning off steam solenoid and COOK light.

E.Buzzer manually shut off by rotating timer to off position.

F.If timer is set to the HOLD position, contacts 21 – 23 remain closed keeping the steam solenoids energized and COOK lights turned on.

2.Power switch set to off position.

A.Power removed from compartment controls and generator control circuit.

B.Time delay relay energized.

1)Delay relay starts 1000-second countdown.

2)Drain solenoid energized for 1000 seconds.

3)Water drained from generator.

F35425 (February 2006)

 

Page 24 of 40

 

Image 24
Contents Convection SteamersTable of Contents Low Level Cut-Off & Differential Control Installation Operation Cleaning Specifications GeneralIntroduction ToolsRemoval and Replacement of Parts Covers and PanelsDoor Assembly Cooking Compartment DoorCabinet Base Left Side Panel Cabinet Base Rear PanelDoor Gasket Door HandleDoor Latch Assembly Compartment ControlsGenerator Assembly Main BurnerGAS Combination Control Valve Covers and Panels Fill and Cold Water Solenoid Valves PILOT/SPARK Probe Flame Sensor Service Procedures and Adjustments Blower AIR Pressure Adjustment AIR Pressure SwitchPilot Burner Adjustment Operating Pressure Switch Thumb Wheel Adjustment Inlet Water/Steam Strainer Automatic Ignition Systems Spark Ignition Control TestManifold Pressure Adjustment Ignition TestLatch Adjustment Cooking CompartmentControls Striker Adjustment Deliming the GeneratorItems Required not provided C24GA Automatic Drain US GAL Capacity Steam GeneratorCooking Cycle Test Probe InspectionGeneral Electrical Operation Water Level ControlsSequence of Operation Low Level Cut-Off and Differential ControlC24GA Series Convection Steamers Electrical Operation Compartment control Units after Dec Schematic Diagrams Generator Schematic DiagramSchematic Diagram Compartment Controls Standard Schematic Diagram Compartment Controls Constant Steam Component Location Cabinet Base Generator Component Function Cabinet Base Generator Blower Air Pressure Switch Super Heater AssemblyDrain Valve Timer Hold ThermostatComponent Location Cooking Compartment Component Function Cooking Compartment Troubleshooting Troubleshooting Sequence of Operation Step Function DescriptionTroubleshooting Chart Symptom Possible CausesSymptom Possible Causes Symptom Possible Causes Condensed Spare Parts List F35425 February

C24GA6 ML-136021, C24GA10 ML-136022, C24GA6, C24GA10, ML-136021, ML-136022 specifications

The Vulcan-Hart C24GA series is renowned in the commercial kitchen industry for its high-quality performance and efficient cooking capabilities. This series includes models C24GA6 and C24GA10, which are designed with versatility and reliability at their core. These models cater to a wide range of culinary demands, ensuring that chefs can prepare a variety of dishes with ease.

The C24GA6 features six powerful burners, providing ample cooking space and heat output for busy kitchens. Its robust construction ensures durability, while an easy-to-clean stainless steel exterior makes maintenance hassle-free. The burners are designed for quick ignition, and the adjustable flame control allows for precise temperature adjustments, ideal for simmering sauces or achieving the perfect sear.

On the other hand, the C24GA10 model is equipped with ten burners, making it suitable for larger establishments that require additional cooking power. Similar to the C24GA6, it incorporates seamless stainless steel components and a design that meets the rigorous demands of a professional kitchen. Both models boast a high BTU output, ensuring that meals are prepared quickly and efficiently, which is essential during peak hours.

The C24GA series also integrates advanced technologies that enhance its functionality. The burners utilize a standing pilot ignition system, ensuring a reliable start-up every time. This technology minimizes downtime and allows chefs to focus on cooking rather than troubleshooting equipment.

In addition to the C24GA series, Vulcan-Hart offers the ML-136021 and ML-136022 models, which complement the cooking arsenal in any kitchen. These models are expertly designed to provide the same level of reliability and performance. They follow the same principles of durability and ease of maintenance that Vulcan-Hart is known for.

The ML-136021 and ML-136022 models feature streamlined designs that fit seamlessly into any workspace. With efficient heat distribution and user-friendly controls, these models are perfect for both experienced chefs and culinary students alike.

Together, the Vulcan-Hart C24GA6, C24GA10, ML-136021, and ML-136022 models represent a comprehensive cooking solution that meets the varied needs of commercial kitchens. With their powerful burners, durable construction, and advanced technologies, these units ensure top-notch performance and efficiency for all cooking requirements.