Sterling 882.93092.01 manual Shipping Information

Page 2

Shipping Information

Unpacking and Inspection

You should inspect your equipment for possible shipping damage. Thoroughly check the equipment for any damage that might have occurred in transit, such as broken or loose wiring and components, loose hardware and mounting screws, etc.

In the Event of Shipping Damage

According to the contract terms and conditions of the Carrier, the responsibility of the Shipper ends at the time and place of shipment.

Notify the transportation company’s local agent if you discover damage

Hold the damaged goods and packing material for the examining agent’s inspection. Do not return any goods before the transportation company’s inspection and authorization.

File a claim with the transportation company. Substantiate the claim by referring to the agent’s report. A certified copy of our invoice is available upon request. The original Bill of Lading is attached to our original invoice. If the shipment was prepaid, write us for a receipted transportation bill.

Advise customer service regarding your wish for assistance and to obtain an RMA (return material authorization) number.

If the Shipment is Not Complete

Check the packing list as back-ordered items are noted on the packing list. In addition to the equipment itself, you should have:

Bill of lading Packing list

Operating and Installation packet

Electrical schematic and panel layout drawings Component instruction manuals (if applicable)

Re-inspect the container and packing material to see if you missed any smaller items during unpacking.

If the Shipment is Not Correct

If the shipment is not what you ordered, contact the parts and service department immediately at (262) 641-8610. Have the order number and item number available. Hold the items until you receive shipping instructions.

Returns

Do not return any damaged or incorrect items until you receive shipping instructions from the shipping department.

GP Series Portable Chillers

ii

Image 2
Contents GP Series Portable Chillers Shipping Information Table of Contents Chapter Troubleshooting Safety Symbols Used in this Manual SafetyHow to Use This Manual  Wear Safety Glasses and Work Gloves ResponsibilityGeneral Description Functional DescriptionModels Covered in This Manual Typical ApplicationsChilled Water Circuit Refrigeration Circuit System ControlStandard Features Mechanical FeaturesElectrical Features Refrigeration FeaturesOther Features Safety Devices and InterlocksController Features Crankcase HeaterHigh Pressure Cutout Remote Start/Stop Interlock Optional FeaturesFlow Switch Mounting Features Electrical Connections InstallationUncrating Process Water Connections Bypass Valve ConsiderationsCondenser Considerations Galvanic Corrosion ConsiderationsWater Treatment Considerations Water-Cooled Chiller CondensersTypical GP20-50 Water Cooled Condenser Connections Air-Cooled Chiller CondensersRemote Air-Cooled Chiller Condensers Towards the condenser GPRC-40 GPRC-105 Discharge Line Sizing Refrigerant Charge Determination Remote Condenser Configurations Water Pumps Three-Phase CompressorsChecking Motor Direction Condenser FanWater Reservoir Part Number DescriptionSuggested Overhead Piping Configuration Pump Automatic Water Make-Up Option Initial Start-UpPage Finishing Setup Setting Up Passwords Supervisor Password to complete the security setup Microprocessor Controller Panel Buttons, Indicator Lights, and SwitchesOperation Main Status Screen Status Screens Operator Setpoints ScreenMain Chiller Status Screen GP Series Portable Chillers Operation Page Access Levels Controller SetpointsGP Series Portable Chillers Operation Menu Screen Operator Setpoints Screen Configuration Settings These configurations are described belowWEB Alarms Optional CommunicationsLubrication MaintenanceFilter Cleaning Maintaining the CondenserEvaporator Process Piping Y-Strainer Preventative Maintenance ServiceMaintaining the Evaporator Troubleshooting Identifying the Cause of a ProblemGP Series Portable Chillers Troubleshooting SC/W System fault GP Series Portable Chillers Troubleshooting Non-Controller Related Issues Problem Possible cause SolutionGP Series Portable Chillers Troubleshooting GP Series Portable Chillers Troubleshooting Technical Assistance AppendixReturned Material Policy Contract Department Service DepartmentSales Department Specifications Air-Cooled Portable ChillersGPAC-40 GPAC-70 GPAC-105 GPAC-175 Water-Cooled Portable Chillers GPWC-20GPWC-40 GPWC-70 GPWC-105 GPWC-175 Pump Curves, Flow, and Pressure Considerations Hertz Pump CurvesALL 60 Hz ALL 50 Hz ALL 50 Hz Calculating Chiller Nominal Flow and Pressure to Process Remote Air-Cooled Chiller Configurations Double Riser Detail Typical Ductwork for Air-Cooled Chillers Water column = Pascal GP Series Portable Chillers Appendix Piping Diagrams GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix

882.93092.01 specifications

The Sterling 882.93092.01 is an impressive timepiece that exemplifies the perfect blend of artistry and precision engineering. This elegant watch is a testament to the craftsmanship that defines the Sterling brand, making it a sought-after choice for both watch aficionados and casual wearers alike.

One of the main features of the Sterling 882.93092.01 is its exceptional movement technology. This watch is powered by a reliable automatic movement, ensuring accurate timekeeping without the need for battery replacements. The self-winding mechanism harnesses the natural motion of the wearer's wrist, providing a seamless and hassle-free experience.

The design of the Sterling 882.93092.01 is another standout characteristic. The watch features a stainless steel case that provides durability and a sleek aesthetic. The polished finish adds a touch of sophistication, making it suitable for both formal and casual settings. With a diameter that fits comfortably on the wrist, it is designed for effortless wear throughout the day.

Additionally, the face of the Sterling 882.93092.01 boasts a striking dial that is not only visually appealing but also functional. It includes clear hour markers and hands that are luminous, facilitating readability in low-light conditions. This thoughtful design element ensures that the wearer can effortlessly check the time at any hour.

Another notable aspect is the watch's water resistance. The Sterling 882.93092.01 is rated for water resistance, making it suitable for everyday wear, including light swimming and exposure to splashes. This feature enhances the watch’s practicality, allowing it to withstand the rigors of daily life without compromising its integrity.

Finally, the bracelet of the Sterling 882.93092.01 is crafted with comfort and style in mind. It features an adjustable clasp that allows for a customized fit, ensuring that the watch remains secure on the wrist. The combination of high-quality materials and impeccable design makes the bracelet an integral part of the overall charm of the watch.

Overall, the Sterling 882.93092.01 is more than just a timekeeping device; it is a statement piece that showcases exceptional design, reliable technology, and outstanding craftsmanship. Whether worn at special occasions or in everyday scenarios, this watch is bound to impress and stand the test of time.