Error and Warning

Displays the current status when changing the settings or formatting drives.

Examples of LCD

 

Meaning

SYSTEM Error

E00

System is not responding. Unplug the power code of the TeraStation and reboot it. If the

MPU No Response

 

error still persists, contact BUFFALO’s service center for repair.

DRAM LINES

E01

Some parts of internal IC is not working properly. Contact BUFFALO’s service center for

DATA Failure

 

repair.

DRAM LINES

E02

Some parts of internal IC is not working properly. Contact BUFFALO’s service center for

ADDRESS Failure

 

repair.

RTC Chip

E03

Some parts of internal IC is not working properly. Unplug the power code of the TeraStation

No RTC Clock

 

and reboot it. The error still persists, contact BUFFALO’s service center for repair.

SYSTEM Error

E04

The firmware is corrupted. Contact BUFFALO’s service center for repair.

Can’t Load Krnl!

 

 

WDT

E05

System hung up. Unplug the power code of the TeraStation and reboot it. If the error still

SYSTEM Stopped

 

persists, contact BUFFALO’s service center for repair.

TFTP MODE

E06

The firmware is corrupted.

Lost boot image

 

Contact BUFFALO’s service center for repair. Wait for 5 minutes to show “E04” and turn off,

 

 

or press and hold the power button for 10 seconds.

HD ALL

E07

Hard disks are not found.

ALL HD Not Found

 

Even if the hard disks are connected but this message is displayed, contact BUFFALO’s

 

 

service center for repair.

UPS

E10

Operating using UPS battery due to the power outage. System will be shut down safely.

Dependent Mode

 

Check the power supplied to UPS, and turn TeraStation off if there is no problem on UPS.

SYSTEM

I10

Temperature in the system may be over the limits of warranty. Do not place any object

TOO HOT!

 

around the TeraStation. Or move the TeraStation to the cooler place.

SYSTEM Error

E11

There is a problem with the number of fan spinning.

Fan Failure

 

Check if there is any objects or dusts on the fan. If you see any objects or dusts, remove them

 

 

by tweezers or an air duster. The error still persists, contact BUFFALO’s service center for

 

 

repair.

SYSTEM Error

E12

Temperature in the system is over the limits of warranty. Do not place any object around the

Cooling Failure

 

TeraStation. Or move the TeraStation to the cooler place.

RAID Error

E13

An error occurs in Xth RAID array. When rebooting the TeraStation, it will run as degrade

ARRAYx Error

 

mode when RAID 1 or RAID 5 is used. You can use an erroneous drive by rebuilding, but it is

 

 

recommended that you replace the erroneous drive immediately.

RAID Arrayx

E14

Xth RAID array could not be mount. Turn off TeraStation, and turn it on again. If the error still

Can’t Mount

 

persists, rebuild RAID. If the error still persists, contact BUFFALO’s service center for repair.

HDx Error

E15

The bad sector in xth hard drive has reached the dangerous zone. Replace Xth hard drive.

Many Bad Sectors

 

 

HDx Error

E16

Cannot find the Xth hard drive.The Xth hard drive may not connected or may be damaged.

HDx Not Found

 

Replace the hard drive.