Using RAID 1 mode
Click [System] - [Storage] - [RAID Array] in the Web Admin interface.
Click the array you want to set.
Click hard disks (Disk 1 and Disk 2, or Disk 3 and Disk 4) in RAID1.

Using RAID 1 mode

1 Change system to normal mode (page 20).

2

3

4 Manual background

5 Manual background

1Select [RAID 1].

2Click [Create Raid Array].

 

Note:

 

After the RAID array is changed, the TeraStation will perfom a RAID check that will take about 5 hours per TB. File

 

transfers will be slower during this period. While the “RAID ARRAY x Resyncing” message is displayed on the LCD

 

screen, do not turn off the TeraStation. If you turn it off, the RAID check will start over.

6

The [Confirm Operation] screen will appear. Enter the number shown in the [Confirmation Number] field within

 

60 seconds, and click [Apply].

7

Follow the instructions displayed on the screen.

You have set up a RAID 1 array. Repeat the steps to create a second RAID 1 array with the other two drives, or refer to page 26 to configure a hot spare with one of the remaining drives. Turn to page 43 to create a shared folder.