Sterling 882.93092.01 manual Main Status Screen

Page 36

Button

Button Description

Detailed description

 

Menu Button

Used to access the menus structure of the PGD interface

 

 

 

 

 

 

On/Off Button

Used to turn the entire chiller On or Off. The button is backlit and will

 

 

turn amber when the chiller is On.

 

 

 

 

Back Button

Used to back up from a menu and return to the main status screen

 

 

 

 

 

 

Up Arrow Button

Used to increment a data field or scroll up within a menu structure.

 

 

 

 

 

 

Enter Button

Used to accept a data field value or to select a menu item.

 

 

 

 

Down Arrow Button

Used to decrement a data field or scroll down within a menu structure.

 

 

 

4-2 Initial Start-up

1. Verify the initial start-up checklist from Chapter 3, Section 3-11.

2. With the main supply power switch in the ON position, the screen will display the version of the software for a period of 5 seconds, and then display the main status screen.

Figure 13: Main Status Screen

3. Set the Leaving Fluid temperature by depressing the

button to display

the menu.

 

Figure 14: Menu Screen

4. Depress the or button to highlight SETPOINTS and press . If passwords were setup (See Section 3-12 for information on the controller passwords) the password screen will appear.

GP Series Portable Chillers

Chapter 4: Operation

36 of 90

Image 36
Contents GP Series Portable Chillers Shipping Information Table of Contents Chapter Troubleshooting Safety How to Use This ManualSafety Symbols Used in this Manual  Wear Safety Glasses and Work Gloves ResponsibilityFunctional Description Models Covered in This ManualGeneral Description Typical ApplicationsChilled Water Circuit Refrigeration Circuit System ControlStandard Features Mechanical FeaturesElectrical Features Refrigeration FeaturesSafety Devices and Interlocks Controller FeaturesOther Features Crankcase HeaterHigh Pressure Cutout Optional Features Flow SwitchRemote Start/Stop Interlock Mounting Features Installation UncratingElectrical Connections Process Water Connections Bypass Valve ConsiderationsGalvanic Corrosion Considerations Water Treatment ConsiderationsCondenser Considerations Water-Cooled Chiller CondensersTypical GP20-50 Water Cooled Condenser Connections Air-Cooled Chiller CondensersRemote Air-Cooled Chiller Condensers Towards the condenser GPRC-40 GPRC-105 Discharge Line Sizing Refrigerant Charge Determination Remote Condenser Configurations Three-Phase Compressors Checking Motor DirectionWater Pumps Condenser FanWater Reservoir Part Number DescriptionSuggested Overhead Piping Configuration Pump Automatic Water Make-Up Option Initial Start-UpPage Finishing Setup Setting Up Passwords Supervisor Password to complete the security setup Panel Buttons, Indicator Lights, and Switches OperationMicroprocessor Controller Main Status Screen Status Screens Operator Setpoints ScreenMain Chiller Status Screen GP Series Portable Chillers Operation Page Access Levels Controller SetpointsGP Series Portable Chillers Operation Menu Screen Operator Setpoints Screen Configuration Settings These configurations are described belowWEB Alarms Optional CommunicationsMaintenance Filter CleaningLubrication Maintaining the CondenserPreventative Maintenance Service Maintaining the EvaporatorEvaporator Process Piping Y-Strainer Troubleshooting Identifying the Cause of a ProblemGP Series Portable Chillers Troubleshooting SC/W System fault GP Series Portable Chillers Troubleshooting Non-Controller Related Issues Problem Possible cause SolutionGP Series Portable Chillers Troubleshooting GP Series Portable Chillers Troubleshooting Appendix Returned Material PolicyTechnical Assistance Service Department Sales DepartmentContract Department Specifications Air-Cooled Portable ChillersGPAC-40 GPAC-70 GPAC-105 GPAC-175 Water-Cooled Portable Chillers GPWC-20GPWC-40 GPWC-70 GPWC-105 GPWC-175 Pump Curves, Flow, and Pressure Considerations Hertz Pump CurvesALL 60 Hz ALL 50 Hz ALL 50 Hz Calculating Chiller Nominal Flow and Pressure to Process Remote Air-Cooled Chiller Configurations Double Riser Detail Typical Ductwork for Air-Cooled Chillers Water column = Pascal GP Series Portable Chillers Appendix Piping Diagrams GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix GP Series Portable Chillers Appendix

882.93092.01 specifications

The Sterling 882.93092.01 is an impressive timepiece that exemplifies the perfect blend of artistry and precision engineering. This elegant watch is a testament to the craftsmanship that defines the Sterling brand, making it a sought-after choice for both watch aficionados and casual wearers alike.

One of the main features of the Sterling 882.93092.01 is its exceptional movement technology. This watch is powered by a reliable automatic movement, ensuring accurate timekeeping without the need for battery replacements. The self-winding mechanism harnesses the natural motion of the wearer's wrist, providing a seamless and hassle-free experience.

The design of the Sterling 882.93092.01 is another standout characteristic. The watch features a stainless steel case that provides durability and a sleek aesthetic. The polished finish adds a touch of sophistication, making it suitable for both formal and casual settings. With a diameter that fits comfortably on the wrist, it is designed for effortless wear throughout the day.

Additionally, the face of the Sterling 882.93092.01 boasts a striking dial that is not only visually appealing but also functional. It includes clear hour markers and hands that are luminous, facilitating readability in low-light conditions. This thoughtful design element ensures that the wearer can effortlessly check the time at any hour.

Another notable aspect is the watch's water resistance. The Sterling 882.93092.01 is rated for water resistance, making it suitable for everyday wear, including light swimming and exposure to splashes. This feature enhances the watch’s practicality, allowing it to withstand the rigors of daily life without compromising its integrity.

Finally, the bracelet of the Sterling 882.93092.01 is crafted with comfort and style in mind. It features an adjustable clasp that allows for a customized fit, ensuring that the watch remains secure on the wrist. The combination of high-quality materials and impeccable design makes the bracelet an integral part of the overall charm of the watch.

Overall, the Sterling 882.93092.01 is more than just a timekeeping device; it is a statement piece that showcases exceptional design, reliable technology, and outstanding craftsmanship. Whether worn at special occasions or in everyday scenarios, this watch is bound to impress and stand the test of time.