Pentair Model 5600 & 5600 Econominder manual Valve Installation and Start-up Procedures

Page 5

Model 5600 & 5600 Econominder®

Valve Installation and Start-up Procedures

1.Place the softener tank where you want to install the unit. NOTE: Be sure the tank is level and on a firm base.

2.During cold weather it is recommended that the installer warm the valve to room temperature before operating.

3.Perform all plumbing according to local plumbing codes.

Use a 1/2" minimum pipe size for the drain.

Use a 3/4" drain line for backwash flow rates that exceed 7 gpm or length that exceeds 20′ (6 m).

4.Cut the 1" distributor tube (1.050 O.D.) flush with top of each tank. NOTE: Only use silicone lubricant.

5.Lubricate the distributor o-ring seal and tank o-ring seal. Place the main control valve on tank.

6.Solder joints near the drain must be done before connecting the Drain Line Flow Control fitting (DLFC). Leave at least 6" (152 mm) between the DLFC and solder joints when soldering pipes that are connected on the DLFC. Failure to do this could cause interior damage to DLFC.

7.Use only Teflon tape on the drain fitting.

8.Be sure the floor under the salt storage tank is clean and level.

9.Place approximately 1" (25 mm) of water above the grid plate. If a grid is not utilized, fill to the top of the air check in the salt tank. Do not add salt to the brine tank at this time.

10.On units with a bypass, place in Bypass position.

Turn on the main water supply.

Open a cold soft water tap nearby and let water run a few minutes or until the system is free of foreign material (usually solder) resulting from the installation. Close the water tap when water runs clean.

11.Place the bypass in the In Service position and let water flow into the mineral tank. When water flow stops, slowly open a cold water tap nearby and let water run until air is purged from the unit. Then close tap.

12.Plug the valve into an approved power source. When the valve has power it drives to the In Service position.

5

Image 5
Contents Model 5600 & 5600 Econominder Table of Contents Control Valve Specifications Job Specification SheetGeneral Residential Installation Check List Valve Installation and Start-up Procedures Model 5600 Softener Control Model 5600 Installation and Start-up ProceduresModel 5600 Backwash Filter Control Before Plugging in the UnitPreliminary Rinse position Cycle Times and Flow DiagramsModel 5600 Econominder Model 5600 Econominder Installation and Start-up ProceduresService Position Water Conditioner Flow DiagramsBackwash Position Water Conditioner Flow Diagrams Cont’dSlow Rinse Position Settling Rinse Position Model 5600 Control Valve Drive Assembly Model 5600 Control Valve Drive AssemblyItem Number No. Req’d Model 5600 and 5600 Econominder Control Valve Drive Assembly Item Number No. Req’d Part Number Description Model 5600 Econominder Control Valve Drive Assembly Model 5600 Econominder Control Valve Drive AssemblyItem Number No. Req’d Bypass Valve Assembly, Plastic Bypass Valve Assembly, PlasticBypass Valve Assembly, Brass Bypass Valve Assembly, BrassModel 5600 Econominder Meter Assembly Model 5600 Econominder Meter AssemblyReplace Time Brine Valve, Injectors and Screen Service InstructionsReplace Timer Service Instructions Cont’dReplace Piston Assembly Replace Seals and Spacers Replace Meter Replace Meter Cover and/or Impeller Problem Cause Correction Model 5600 and 5600 Econominder TroubleshootingGeneral Service Hints for Meter Control Model 5600 and 5600 Econominder Troubleshooting Cont’dModel 5600SF Troubleshooting Service Assemblies Model 5600 & 5600 Econominder Model 5600 & 5600 Econominder Page 40106 Rev. H 05/05