Pentair Model 5600 & 5600 Econominder manual Model 5600 and 5600 Econominder Troubleshooting

Page 29

Model 5600 & 5600 Econominder®

Model 5600 and 5600 Econominder Troubleshooting

 

PROBLEM

 

CAUSE

 

CORRECTION

 

 

 

 

 

 

1.

Softener fails to regenerate.

A.

Electrical service to unit has been

A.

Assure permanent electrical service

 

 

 

interrupted.

 

(check fuse, plug, pull chain or

 

 

 

 

 

switch).

 

 

B.

Timer is defective.

B.

Replace timer.

 

 

C.

Power failure.

C.

Reset time of day.

 

 

 

 

 

 

2.

Softener delivers hard water.

A.

Bypass valve is open.

A.

Close bypass valve.

 

 

B.

No salt in brine tank.

B.

Add salt to brine tank and maintain

 

 

 

 

 

salt level above water level.

 

 

C.

Injectors or screen is plugged.

C.

Replace injectors and screen.

 

 

D.

Insufficient water flowing into brine tank.

D.

Check brine tank fill time and clean

 

 

 

 

 

brine line flow control if plugged.

 

 

E.

Hard water tank hardness.

E.

Repeated flushings of the hot water

 

 

 

 

 

tank is required.

 

 

F.

Leak at distributor tube.

F.

Make sure distributor tube is not

 

 

 

 

 

cracked. Check o-ring and tube pilot.

 

 

G.

Internal valve leak.

G.

Replace seals and spacers and/or

 

 

 

 

 

piston.

3.

Unit uses too much salt.

A.

Improper salt setting.

A.

Check salt usage and salt setting.

 

 

B.

Excess water in brine tank.

B. See problem number 7.

 

 

 

 

 

 

4.

Loss of water pressure.

A.

Iron build-up in line to water conditioner.

A.

Clean line to water conditioner.

 

 

B.

Iron build-up in water conditioner.

B.

Clean control and add resin cleaner to

 

 

 

 

 

resin bed. Increase frequency of

 

 

 

 

 

regeneration.

 

 

C.

Inlet of control plugged due to foreign

C.

Remove piston and clean control.

 

 

 

material loose from pipes by recent work

 

 

 

 

 

done on plumbing system.

 

 

5.

Loss of resin through drain line.

A.

Air in water system.

A.

Assure that well system has proper air

 

 

 

 

 

elimination control, check for dry

 

 

 

 

 

well condition.

6.

Iron in conditioned water.

A.

Fouled resin bed.

A.

Check backwash, brine draw and

 

 

 

 

 

brine tank fill, increase frequency of

 

 

 

 

 

regeneration, increase backwash

 

 

 

 

 

time.

7.

Excessive water in brine tank.

A.

Plugged drain line flow control.

A.

Clean flow control.

8.

Salt water in service line.

A.

Plugged injector system.

A.

Clean injector and replace screen.

 

 

B.

Timer not cycling.

B.

Replace timer.

 

 

C.

Foreign material in brine valve.

C. Clean or replace brine valve.

 

 

D.

Foreign material in brine line flow control.

D.

Clean brine line flow control.

 

 

 

 

 

 

29

Image 29
Contents Model 5600 & 5600 Econominder Table of Contents Control Valve Specifications Job Specification SheetGeneral Residential Installation Check List Valve Installation and Start-up Procedures Model 5600 Softener Control Model 5600 Installation and Start-up ProceduresModel 5600 Backwash Filter Control Before Plugging in the UnitPreliminary Rinse position Cycle Times and Flow DiagramsModel 5600 Econominder Model 5600 Econominder Installation and Start-up ProceduresService Position Water Conditioner Flow DiagramsBackwash Position Water Conditioner Flow Diagrams Cont’dSlow Rinse Position Settling Rinse Position Model 5600 Control Valve Drive Assembly Model 5600 Control Valve Drive AssemblyItem Number No. Req’d Model 5600 and 5600 Econominder Control Valve Drive Assembly Item Number No. Req’d Part Number Description Model 5600 Econominder Control Valve Drive Assembly Model 5600 Econominder Control Valve Drive AssemblyItem Number No. Req’d Bypass Valve Assembly, Plastic Bypass Valve Assembly, PlasticBypass Valve Assembly, Brass Bypass Valve Assembly, BrassModel 5600 Econominder Meter Assembly Model 5600 Econominder Meter AssemblyReplace Time Brine Valve, Injectors and Screen Service InstructionsReplace Timer Service Instructions Cont’dReplace Piston Assembly Replace Seals and Spacers Replace Meter Replace Meter Cover and/or Impeller Problem Cause Correction Model 5600 and 5600 Econominder TroubleshootingGeneral Service Hints for Meter Control Model 5600 and 5600 Econominder Troubleshooting Cont’dModel 5600SF Troubleshooting Service Assemblies Model 5600 & 5600 Econominder Model 5600 & 5600 Econominder Page 40106 Rev. H 05/05