Model 5600 & 5600 Econominder®
Model 5600 and 5600 Econominder Troubleshooting
| PROBLEM |
| CAUSE |
| CORRECTION |
|
|
|
|
|
|
1. | Softener fails to regenerate. | A. | Electrical service to unit has been | A. | Assure permanent electrical service |
|
|
| interrupted. |
| (check fuse, plug, pull chain or |
|
|
|
|
| switch). |
|
| B. | Timer is defective. | B. | Replace timer. |
|
| C. | Power failure. | C. | Reset time of day. |
|
|
|
|
|
|
2. | Softener delivers hard water. | A. | Bypass valve is open. | A. | Close bypass valve. |
|
| B. | No salt in brine tank. | B. | Add salt to brine tank and maintain |
|
|
|
|
| salt level above water level. |
|
| C. | Injectors or screen is plugged. | C. | Replace injectors and screen. |
|
| D. | Insufficient water flowing into brine tank. | D. | Check brine tank fill time and clean |
|
|
|
|
| brine line flow control if plugged. |
|
| E. | Hard water tank hardness. | E. | Repeated flushings of the hot water |
|
|
|
|
| tank is required. |
|
| F. | Leak at distributor tube. | F. | Make sure distributor tube is not |
|
|
|
|
| cracked. Check |
|
| G. | Internal valve leak. | G. | Replace seals and spacers and/or |
|
|
|
|
| piston. |
3. | Unit uses too much salt. | A. | Improper salt setting. | A. | Check salt usage and salt setting. |
|
| B. | Excess water in brine tank. | B. See problem number 7. | |
|
|
|
|
|
|
4. | Loss of water pressure. | A. | Iron | A. | Clean line to water conditioner. |
|
| B. | Iron | B. | Clean control and add resin cleaner to |
|
|
|
|
| resin bed. Increase frequency of |
|
|
|
|
| regeneration. |
|
| C. | Inlet of control plugged due to foreign | C. | Remove piston and clean control. |
|
|
| material loose from pipes by recent work |
|
|
|
|
| done on plumbing system. |
|
|
5. | Loss of resin through drain line. | A. | Air in water system. | A. | Assure that well system has proper air |
|
|
|
|
| elimination control, check for dry |
|
|
|
|
| well condition. |
6. | Iron in conditioned water. | A. | Fouled resin bed. | A. | Check backwash, brine draw and |
|
|
|
|
| brine tank fill, increase frequency of |
|
|
|
|
| regeneration, increase backwash |
|
|
|
|
| time. |
7. | Excessive water in brine tank. | A. | Plugged drain line flow control. | A. | Clean flow control. |
8. | Salt water in service line. | A. | Plugged injector system. | A. | Clean injector and replace screen. |
|
| B. | Timer not cycling. | B. | Replace timer. |
|
| C. | Foreign material in brine valve. | C. Clean or replace brine valve. | |
|
| D. | Foreign material in brine line flow control. | D. | Clean brine line flow control. |
|
|
|
|
|
|