![](/images/new-backgrounds/1074553/7455313x1.webp)
Model 5600 & 5600 Econominder®
Model 5600 Backwash Filter Installation and
NOTE: Install the water softener with the inlet, outlet and drain connections made according to manufacturer’s recommendations and to meet applicable plumbing codes.
Manual |
| |
Regeneration Knob | ||
| Skipper Wheel | |
Red Time | (shows every | |
other day | ||
Set Button | ||
backwash) | ||
|
Time of Day Arrow | Red Pointer |
Figure 2: Model 5600 Backwash Filter Control
Before Plugging in the Unit
1.Open a treated water tap down stream of the filter.
2.Manually index the filter to the In Service position and allow the mineral tank to fill by slowly opening the main water supply valve. Any bypass should be in the In Service position.
NOTE: The water flowing from the downstream tap is cloudy and/or contains media fines as well as air. Allow the water to run until it appears clean and free of air.
3.When a steady clean flow appears at the tap, close the tap and the main water supply valve and allow the filter media bed to settle for
4.Manually index the filter to the Backwash position.
5.To prevent a sudden surge of water and air, partially open the main water supply valve so that the flow at the drain of the filter is approximately 1 gpm. The water at the drain is cloudy again and/or contains media fines as well as air. Allow water to flow at the drain until it appears clean and free of air.
6.Continue to open the water supply valve until it is completely open. Allow water to flow at the drain until all media fines are washed out of the filter.
7.Manually index the filter to the In Service position, and again open the downstream tap. Check to be sure that the water flows clear. If necessary, allow water to flow until all media fines are gone. If the tap is equipped with an aerator check that is not plugged with media fines and pipe scale.
8.Plug in the electrical cord and look in the sight hole on the back of the timer motor to ensure that it is running. Set the days backwashing is to occur by sliding tabs on the skipper wheel outward to expose trip fingers. Each tab is one day. Finger at red pointer is tonight. Moving clockwise from red pointer, extend or retract fingers to obtain the desired backwash schedule.
9.Set time of day by pushing red button and spin the
7