Pentair 40106 Rev. H 05/05 manual Service Instructions Cont’d, Replace Timer

Page 24

Model 5600 & 5600 Econominder®

Service Instructions (Cont’d.)

Replace Timer

1.Unplug electrical cord from outlet.

2.Turn off water supply to conditioner:

If the conditioner installation has a “three valve” bypass system, first open the valve in the bypass line, then close the valves at the conditioner inlet and outlet.

If the conditioner has an integral bypass valve, put it in the Bypass position.

If there is only a shut-off valve near the conditioner inlet, close it.

3.Relieve water pressure in the conditioner by putting the control in the Backwash position momentarily. Return the control to the In Service position.

4.Pull cable out of meter cover. Remove the control valve back cover.

5.Remove screw and washer at drive yoke. Remove timer mounting screws. The entire timer assembly now lifts off easily.

6.Put new timer on top of valve. Be sure drive pin on main gear engages slot in drive yoke (rotate control knob if necessary).

7.Replace timer mounting screws. Replace screw and washer at drive yoke.

8.Return bypass or inlet valving to normal In Service position. Water pressure automatically builds in the conditioner. NOTE: Be sure to shut off any bypass line.

9.Plug electrical cord into outlet.

10.Set time of day, program wheel, and salt usage. Cycle the control valve manually to assure proper function. Be sure to return the control valve to the In Service position.

11.Replace the control valve back cover. Be sure grommet at cable hole is in place.

12.Make sure there is enough brine in the brine tank.

13.Rotate program wheel counterclockwise until it stops at Regeneration position.

14.Start regeneration cycle manually if water is hard.

15.Plug cable into meter cover, rotate cable to align drive flat if necessary.

24

Image 24
Contents Model 5600 & 5600 Econominder Table of Contents Job Specification Sheet Control Valve SpecificationsGeneral Residential Installation Check List Valve Installation and Start-up Procedures Model 5600 Installation and Start-up Procedures Model 5600 Softener ControlBefore Plugging in the Unit Model 5600 Backwash Filter ControlCycle Times and Flow Diagrams Preliminary Rinse positionModel 5600 Econominder Installation and Start-up Procedures Model 5600 EconominderWater Conditioner Flow Diagrams Service PositionWater Conditioner Flow Diagrams Cont’d Backwash PositionSlow Rinse Position Settling Rinse Position Model 5600 Control Valve Drive Assembly Model 5600 Control Valve Drive AssemblyItem Number No. Req’d Model 5600 and 5600 Econominder Control Valve Drive Assembly Item Number No. Req’d Part Number Description Model 5600 Econominder Control Valve Drive Assembly Model 5600 Econominder Control Valve Drive AssemblyItem Number No. Req’d Bypass Valve Assembly, Plastic Bypass Valve Assembly, PlasticBypass Valve Assembly, Brass Bypass Valve Assembly, BrassModel 5600 Econominder Meter Assembly Model 5600 Econominder Meter AssemblyService Instructions Replace Time Brine Valve, Injectors and ScreenService Instructions Cont’d Replace TimerReplace Piston Assembly Replace Seals and Spacers Replace Meter Replace Meter Cover and/or Impeller Model 5600 and 5600 Econominder Troubleshooting Problem Cause CorrectionModel 5600 and 5600 Econominder Troubleshooting Cont’d General Service Hints for Meter ControlModel 5600SF Troubleshooting Service Assemblies Model 5600 & 5600 Econominder Model 5600 & 5600 Econominder Page 40106 Rev. H 05/05