Pentair Model 5600 & 5600 Econominder, 40106 Rev. H 05/05 manual Model 5600SF Troubleshooting

Page 31

Model 5600 & 5600 Econominder®

Model 5600SF Troubleshooting

 

PROBLEM

 

CAUSE

 

CORRECTION

 

 

 

 

 

1. Filter fails to backwash.

A.

Electrical service to unit has been

A.

Assure permanent electrical service

 

 

 

interrupted.

 

(check fuse, plug, pull chain or

 

 

 

 

 

switch).

 

 

B.

Timer is defective.

B.

Replace timer.

 

 

C.

Power failure.

C.

Reset time of day.

 

 

 

 

 

 

2.

Filter "bleeds" iron.

A.

Bypass valve is open.

A.

Close bypass valve.

 

 

B.

Excessive water usage.

B.

Reduce days between, backwashing

 

 

 

 

 

(see timer instructions), make sure

 

 

 

 

 

that there is not a leaking valve in the

 

 

 

 

 

toilet bowl or sinks.

 

 

C.

Hot water tank rusty.

C.

Repeated flushings of the hot water

 

 

 

 

 

tank is required.

 

 

D.

Leak at distributor tube.

D.

Make sure distributor tube is not

 

 

 

 

 

cracked, check o-ring and tube pilot.

 

 

E.

Defective or stripped filter medium bed.

E.

Replace bed.

 

 

F.

Inadequate backwash flow rate.

F.

Make sure filter has correct drain

 

 

 

 

 

flow control, be sure flow control is

 

 

 

 

 

not clogged or drain line restricted, be

 

 

 

 

 

sure water pressure has not dropped,

 

 

 

 

 

increase backwash flow rate

 

 

 

 

 

according to specifications for your

 

 

 

 

 

unit, see your dealer for

 

 

 

 

 

recommendations.

3.

Loss of water pressure.

A.

Iron or turbidity build-up in water filter.

A.

Reduce days between backwashing

 

 

 

 

 

so filter backwashes more often,

 

 

 

 

 

make sure filter is sized large enough

 

 

 

 

 

to handle water usage.

 

 

B.

Inlet plugged due to foreign material

B.

Remove piston and clean control.

 

 

 

broken loose from pipes by recent work

 

 

 

 

 

done on plumbing system.

 

 

4. Loss of filter medium through

A.

Broken or missing top screen.

A.

Replace top screen, must have 0.020"

 

drain line.

 

 

 

wide slots.

5.

Drain flows continuously.

A.

Foreign material in control.

A.

Remove piston assembly and inspect

 

 

 

 

 

bore, remove foreign material and

 

 

 

 

 

check control in various cycle

 

 

 

 

 

positions.

 

 

B.

Internal control leak.

B. Replace seals and/or piston assembly.

 

 

C.

Control valve jammed in rinse or

C.

Replace piston, seals and spacers

 

 

 

backwash.

 

(and drive motor if necessary).

31

Image 31
Contents Model 5600 & 5600 Econominder Table of Contents Control Valve Specifications Job Specification SheetGeneral Residential Installation Check List Valve Installation and Start-up Procedures Model 5600 Softener Control Model 5600 Installation and Start-up ProceduresModel 5600 Backwash Filter Control Before Plugging in the UnitPreliminary Rinse position Cycle Times and Flow DiagramsModel 5600 Econominder Model 5600 Econominder Installation and Start-up ProceduresService Position Water Conditioner Flow DiagramsBackwash Position Water Conditioner Flow Diagrams Cont’dSlow Rinse Position Settling Rinse Position Model 5600 Control Valve Drive Assembly Model 5600 Control Valve Drive AssemblyItem Number No. Req’d Model 5600 and 5600 Econominder Control Valve Drive Assembly Item Number No. Req’d Part Number Description Model 5600 Econominder Control Valve Drive Assembly Model 5600 Econominder Control Valve Drive AssemblyItem Number No. Req’d Bypass Valve Assembly, Plastic Bypass Valve Assembly, PlasticBypass Valve Assembly, Brass Bypass Valve Assembly, BrassModel 5600 Econominder Meter Assembly Model 5600 Econominder Meter AssemblyReplace Time Brine Valve, Injectors and Screen Service InstructionsReplace Timer Service Instructions Cont’dReplace Piston Assembly Replace Seals and Spacers Replace Meter Replace Meter Cover and/or Impeller Problem Cause Correction Model 5600 and 5600 Econominder TroubleshootingGeneral Service Hints for Meter Control Model 5600 and 5600 Econominder Troubleshooting Cont’dModel 5600SF Troubleshooting Service Assemblies Model 5600 & 5600 Econominder Model 5600 & 5600 Econominder Page 40106 Rev. H 05/05