Model 5600 & 5600 Econominder®
Model 5600SF Troubleshooting
| PROBLEM |
| CAUSE |
| CORRECTION |
|
|
|
|
| |
1. Filter fails to backwash. | A. | Electrical service to unit has been | A. | Assure permanent electrical service | |
|
|
| interrupted. |
| (check fuse, plug, pull chain or |
|
|
|
|
| switch). |
|
| B. | Timer is defective. | B. | Replace timer. |
|
| C. | Power failure. | C. | Reset time of day. |
|
|
|
|
|
|
2. | Filter "bleeds" iron. | A. | Bypass valve is open. | A. | Close bypass valve. |
|
| B. | Excessive water usage. | B. | Reduce days between, backwashing |
|
|
|
|
| (see timer instructions), make sure |
|
|
|
|
| that there is not a leaking valve in the |
|
|
|
|
| toilet bowl or sinks. |
|
| C. | Hot water tank rusty. | C. | Repeated flushings of the hot water |
|
|
|
|
| tank is required. |
|
| D. | Leak at distributor tube. | D. | Make sure distributor tube is not |
|
|
|
|
| cracked, check |
|
| E. | Defective or stripped filter medium bed. | E. | Replace bed. |
|
| F. | Inadequate backwash flow rate. | F. | Make sure filter has correct drain |
|
|
|
|
| flow control, be sure flow control is |
|
|
|
|
| not clogged or drain line restricted, be |
|
|
|
|
| sure water pressure has not dropped, |
|
|
|
|
| increase backwash flow rate |
|
|
|
|
| according to specifications for your |
|
|
|
|
| unit, see your dealer for |
|
|
|
|
| recommendations. |
3. | Loss of water pressure. | A. | Iron or turbidity | A. | Reduce days between backwashing |
|
|
|
|
| so filter backwashes more often, |
|
|
|
|
| make sure filter is sized large enough |
|
|
|
|
| to handle water usage. |
|
| B. | Inlet plugged due to foreign material | B. | Remove piston and clean control. |
|
|
| broken loose from pipes by recent work |
|
|
|
|
| done on plumbing system. |
|
|
4. Loss of filter medium through | A. | Broken or missing top screen. | A. | Replace top screen, must have 0.020" | |
| drain line. |
|
|
| wide slots. |
5. | Drain flows continuously. | A. | Foreign material in control. | A. | Remove piston assembly and inspect |
|
|
|
|
| bore, remove foreign material and |
|
|
|
|
| check control in various cycle |
|
|
|
|
| positions. |
|
| B. | Internal control leak. | B. Replace seals and/or piston assembly. | |
|
| C. | Control valve jammed in rinse or | C. | Replace piston, seals and spacers |
|
|
| backwash. |
| (and drive motor if necessary). |
31