Model 5600 & 5600 Econominder®

Model 5600 and 5600 Econominder Troubleshooting (Cont’d.)

 

PROBLEM

 

CAUSE

 

CORRECTION

 

 

 

 

 

9.

Softener fails to draw brine.

A.

Draw line flow control is plugged.

A. Clean drain line flow control.

 

 

B.

Injector is plugged.

B.

Clean or replace injectors.

 

 

C.

Injector screen plugged.

C.

Replace screen.

 

 

D.

Line pressure is too low.

D.

Increase line pressure (minimum 20

 

 

 

 

 

psi at all times).

 

 

E.

Internal control leak.

E. Change seals, spacers and/or piston

 

 

 

 

 

assembly.

10.

Control cycles continuously.

A.

Faulty timer mechanism.

A.

Replace timer.

11.

Drain flows continuously.

A.

Foreign material in control.

A.

Remove piston assembly and inspect

 

 

 

 

 

bore, remove foreign material and

 

 

 

 

 

check control in various regeneration

 

 

 

 

 

positions.

 

 

B.

Internal control leak.

B. Replace seals and/or piston assembly.

 

 

C.

Control valve jammed in Brine or

C.

Replace seals and/or piston assembly.

 

 

 

Backwash position.

 

 

 

 

D.

Timer motor stopped or jammed.

D.

Replace timer.

 

 

 

 

 

 

General Service Hints for Meter Control

PROBLEM

 

CAUSE

CORRECTION

 

 

 

 

Softener delivers hard water.

A.

Reserve capacity has been exceeded.

A. Check salt dosage requirements and

 

 

 

reset program wheel to provide

 

 

 

additional reserve.

 

B. Program wheel is not rotating with meter

B. Pull cable out of meter cover and

 

 

output.

rotate manually, program wheel

 

 

 

must move without binding and

 

 

 

clutch must give positive "clicks"

 

 

 

when program wheel strikes

 

 

 

regeneration stop (if not, replace

 

 

 

timer).

 

C.

Meter is not measuring flow.

C. Check output by observing rotation

 

 

 

of small gear on front of timer

 

 

 

(program wheel must not be against

 

 

 

regeneration stop for this check)

 

 

 

each tooth to tooth is approximately

 

 

 

30 gallons (if not, replace meter).

30

Image 30
Contents Model 5600 & 5600 Econominder Table of Contents Job Specification Sheet Control Valve SpecificationsGeneral Residential Installation Check List Valve Installation and Start-up Procedures Model 5600 Installation and Start-up Procedures Model 5600 Softener ControlBefore Plugging in the Unit Model 5600 Backwash Filter ControlCycle Times and Flow Diagrams Preliminary Rinse positionModel 5600 Econominder Installation and Start-up Procedures Model 5600 EconominderWater Conditioner Flow Diagrams Service PositionWater Conditioner Flow Diagrams Cont’d Backwash PositionSlow Rinse Position Settling Rinse Position Model 5600 Control Valve Drive Assembly Model 5600 Control Valve Drive AssemblyItem Number No. Req’d Model 5600 and 5600 Econominder Control Valve Drive Assembly Item Number No. Req’d Part Number Description Model 5600 Econominder Control Valve Drive Assembly Model 5600 Econominder Control Valve Drive AssemblyItem Number No. Req’d Bypass Valve Assembly, Plastic Bypass Valve Assembly, PlasticBypass Valve Assembly, Brass Bypass Valve Assembly, BrassModel 5600 Econominder Meter Assembly Model 5600 Econominder Meter AssemblyService Instructions Replace Time Brine Valve, Injectors and ScreenService Instructions Cont’d Replace TimerReplace Piston Assembly Replace Seals and Spacers Replace Meter Replace Meter Cover and/or Impeller Model 5600 and 5600 Econominder Troubleshooting Problem Cause CorrectionModel 5600 and 5600 Econominder Troubleshooting Cont’d General Service Hints for Meter ControlModel 5600SF Troubleshooting Service Assemblies Model 5600 & 5600 Econominder Model 5600 & 5600 Econominder Page 40106 Rev. H 05/05