GE ZV900 Connect Electrical, Verify that power is turned off at the source

Page 14

Installation Instructions

INSTALLATION—VENTED TO THE OUTSIDE

8 CONNECT ELECTRICAL

Verify that power is turned off at the source.

WARNING: If house wiring is not 2-wire with a ground wire, a ground must be provided by the installer. When house wiring is aluminum, be sure to use U.L. approved anti-oxidant compound and aluminum-to-copper connectors.

AVERTISSEMENT :

Si la maison n’est pas câblee avec deux fils et un fil de terre, l’installateur doit installer un fil de terre. Quand les fils sont en aluminium, il faut prendre soin d’utiliser des connecteurs aluminium à cuivre avec une pâte antioxydante approuvée par U.L.

Remove junction box cover and knockout on the left side.

Knockout

J-Box cover

Secure the house wiring to the junction box with a strain relief.

House wiring

J-Box cover

Connect white leads to branch circuit white lead.

Connect black leads to branch circuit black lead.

Connect green/yellow leads to branch circuit green lead or bare ground lead.

Secure all connections with wire nuts on each electrical connector.

Push wires into junction box and replace cover. Be sure wires are not pinched.

Secure J-Box cover with original screw.

13

Image 14
Contents Installation Instructions Rear Wall Mounting Template Before YOU Begin Contents Installation OptionsImportant Please read carefully Power SupplyAdvance Planning Do not use flexible plastic ducting Duct FittingsFlexible ducting Remove the Packaging Tools and Materials Required not Supplied30 Max Determine Installation HeightHood 36 Min Vent hood must be installed 24″ min. 11-1/2 Hood Thumb Attachment Screws Check Installation HardwareFasteners Wood 23-7/8 Ceiling ducting DUCTWORK, Wiring LocationsInstall Framing for Hood Support Wall DuctingCheck to be sure that the bracket is level Install Mounting BracketInstall Duct Bracket Secure the bracket to the wallPrepare the Hood Connect Ductwork Mount the HoodLevel the Hood Screw ScrewVerify that power is turned off at the source Connect ElectricalFinalize Installation Install Duct CoversInstall Filters INSTALLATION-RECIRCULATING Important Framing must be capable of supporting 100 lbsInstall Mounting Bracket Bottom view Dimension by 1″ to Facilitate installation Size and CUT Duct PieceMetal filter Install Duct Covers Install FiltersCharcoal filter Remove all tape and packing materialFor Monogram local service in your area, call
Related manuals
Manual 12 pages 60.71 Kb

ZV900 specifications

The GE ZV900 is a state-of-the-art multi-gas monitoring solution designed for both industrial and environmental applications. Known for its accuracy, reliability, and advanced features, the ZV900 plays a crucial role in ensuring compliance with safety regulations and environmental standards.

One of the standout features of the GE ZV900 is its ability to measure a wide range of gases, including but not limited to carbon dioxide (CO2), oxygen (O2), nitrogen oxides (NOx), and particulates. This versatility makes it an ideal choice for facilities that require comprehensive air quality monitoring.

The ZV900 utilizes cutting-edge technology that incorporates advanced sensors and data analysis algorithms, allowing for real-time monitoring and reporting of gas concentrations. The high precision of these sensors ensures that users receive accurate and reliable data, which is critical when making operational decisions or responding to potential hazards.

In terms of connectivity, the GE ZV900 is equipped with options that support various communication protocols, such as MODBUS, BACnet, and Ethernet. This connectivity enables seamless integration into existing automation and monitoring systems, enhancing the overall functionality of the monitoring setup. Users can also access data remotely through cloud-based platforms, facilitating easier management and analysis of air quality metrics.

Another significant characteristic of the ZV900 is its user-friendly interface. The device features an intuitive touchscreen display that allows operators to easily navigate through different settings and view real-time data. This design ensures that even personnel with minimal training can effectively use the system to monitor gas concentrations and react to alerts.

Moreover, the GE ZV900 is built with durability in mind. It is designed to withstand harsh environmental conditions, making it suitable for various applications, including power generation, manufacturing, and environmental monitoring. The robust construction ensures longevity and reduces the need for frequent maintenance.

In conclusion, the GE ZV900 is a powerful, versatile, and reliable solution for multi-gas monitoring. Its advanced technologies, user-friendly design, and wide range of applications make it an essential tool for industries focused on safety and environmental stewardship. With the capability to provide real-time data and integrate seamlessly into existing systems, the ZV900 stands out as an essential asset in the quest for cleaner, safer air.