GE ZV900 installation instructions Advance Planning, Power Supply, Important Please read carefully

Page 5

Installation Preparation

ADVANCE PLANNING

Determine the exact location of the vent hood.

Use metal ductwork only. These hoods must use

Plan the route for venting exhaust to the outdoors.

8round duct.

Use the shortest and straightest duct route possible. For

Install a wall cap with damper or roof cap at the exterior

satisfactory performance, duct run should not exceed 100 ft.

opening. Order the wall or roof cap and any transition

equivalent length for any duct configurations.

needed in advance.

Refer to “Duct Fittings” chart to compute the maximum

Wall Framing for Adequate Support

permissible length for duct runs to the outdoors.

This vent hood is heavy. Adequate structural support must

CAUTION:To reduce risk of fire and to properly

secured to vertical studs in the wall, or to a horizontal

 

be provided in all types of installations. The hood must be

exhaust air, be sure to duct air outside—do not vent exhaust

support.

air into spaces within walls or ceilings or into attics, crawl

The vent hood should be on site before final framing and

spaces or garages.

PRUDENCE :Il faut prendre soin d’installer un

wall finishing. This will help to accurately locate the duct

work and electrical service.

conduit vers l’extérieur pour réduire le risque d’incendie et

Installation will be easier if the vent hood is installed before

pouvoir évacuer l’air correctement. Il ne faut pas évacuer l’air

the cooktop and countertop are installed.

correctement. Il ne faut pas évacuer l’air dans l’espace entre

Accessory Duct Cover

les parois d’un mur, un plafond ou un grenier, un espace

This hood is shipped with a decorative duct cover for ceiling

sanitaire ou un garage.

 

heights of 711to 95. ZX90010 duct cover accessory

 

is available to reach 96to 105ceiling heights. The

 

accessory should be ordered with the hood and be

 

on site before installation begins.

 

 

 

 

POWER SUPPLY

Grounding instructions

IMPORTANT – (Please read carefully)

WARNING: FOR PERSONAL SAFETY, THIS

The grounding conductor must be connected to a grounded

metal, permanent wiring system, or an equipment-grounding

APPLIANCE MUST BE PROPERLY GROUNDED.

terminal or lead on the hood.

AVERTISSEMENT :POUR DES RAISONS DE

WARNING:The improper connection of the

SÉCURITÉ, CET APPAREIL DOIT ÊTRE CORRECTEMENT MISE

equipment-grounding conductor can result in a risk of

À LA TERRE.

electric shock. Check with a qualified electrician or service

Remove house fuse or open circuit breaker before beginning

representative if you are in doubt whether the appliance is

installation.

properly grounded.

Do not use an extension cord or adapter plug with this

AVERTISSEMENT : Le mauvais branchement du

appliance. Follow National electrical codes or prevailing local

codes and ordinances.

fil de mise à la terre peut causer un choc électrique. En cas de

doute, consulter un électricien qualifié ou un technicien pour

Electrical supply

déterminer si l’appareil est à la terre.

These vent hoods must be supplied with 120V, 60Hz, and

CAUTION:Automatically Operated Device –

connected to an individual, properly grounded branch circuit,

and protected by a 15 or 20 amp circuit breaker or time delay

To reduce the risk of injury disconnect from power supply

fuse.

before servicing. This unit is equipped with an integral

Wiring must be 2 wire with ground.

disconnecting switch located inside the blower housing.

PRUDENCE :Appareil commandé

If the electrical supply does not meet the above

 

requirements, call a licensed electrician before proceeding.

automatiquement. Afin de réduire les risques de blessure,

Route house wiring as close to the installation location as

débranchez l’appareil de l’alimentation électrique avant de

possible, in the ceiling or back wall.

procéder à une réparation. L’appareil est équipé d’un

Connect the hood wiring to the house wiring in accordance

sectionneur intégral situé à l’intérieur du logement du

with local codes.

ventilateur.

 

 

4

Image 5
Contents Installation Instructions Rear Wall Mounting Template Before YOU Begin Installation Options ContentsImportant Please read carefully Power SupplyAdvance Planning Do not use flexible plastic ducting Duct FittingsFlexible ducting Tools and Materials Required not Supplied Remove the Packaging30 Max Determine Installation HeightHood 36 Min Vent hood must be installed 24″ min. 11-1/2 Hood Thumb Attachment Screws Check Installation HardwareFasteners Wood 23-7/8 Install Framing for Hood Support DUCTWORK, Wiring LocationsCeiling ducting Wall DuctingInstall Duct Bracket Install Mounting BracketCheck to be sure that the bracket is level Secure the bracket to the wallPrepare the Hood Level the Hood Mount the HoodConnect Ductwork Screw ScrewConnect Electrical Verify that power is turned off at the sourceFinalize Installation Install Duct CoversInstall Filters Important Framing must be capable of supporting 100 lbs INSTALLATION-RECIRCULATINGInstall Mounting Bracket Bottom view Size and CUT Duct Piece Dimension by 1″ to Facilitate installationCharcoal filter Install Duct Covers Install FiltersMetal filter Remove all tape and packing materialFor Monogram local service in your area, call
Related manuals
Manual 12 pages 60.71 Kb

ZV900 specifications

The GE ZV900 is a state-of-the-art multi-gas monitoring solution designed for both industrial and environmental applications. Known for its accuracy, reliability, and advanced features, the ZV900 plays a crucial role in ensuring compliance with safety regulations and environmental standards.

One of the standout features of the GE ZV900 is its ability to measure a wide range of gases, including but not limited to carbon dioxide (CO2), oxygen (O2), nitrogen oxides (NOx), and particulates. This versatility makes it an ideal choice for facilities that require comprehensive air quality monitoring.

The ZV900 utilizes cutting-edge technology that incorporates advanced sensors and data analysis algorithms, allowing for real-time monitoring and reporting of gas concentrations. The high precision of these sensors ensures that users receive accurate and reliable data, which is critical when making operational decisions or responding to potential hazards.

In terms of connectivity, the GE ZV900 is equipped with options that support various communication protocols, such as MODBUS, BACnet, and Ethernet. This connectivity enables seamless integration into existing automation and monitoring systems, enhancing the overall functionality of the monitoring setup. Users can also access data remotely through cloud-based platforms, facilitating easier management and analysis of air quality metrics.

Another significant characteristic of the ZV900 is its user-friendly interface. The device features an intuitive touchscreen display that allows operators to easily navigate through different settings and view real-time data. This design ensures that even personnel with minimal training can effectively use the system to monitor gas concentrations and react to alerts.

Moreover, the GE ZV900 is built with durability in mind. It is designed to withstand harsh environmental conditions, making it suitable for various applications, including power generation, manufacturing, and environmental monitoring. The robust construction ensures longevity and reduces the need for frequent maintenance.

In conclusion, the GE ZV900 is a powerful, versatile, and reliable solution for multi-gas monitoring. Its advanced technologies, user-friendly design, and wide range of applications make it an essential tool for industries focused on safety and environmental stewardship. With the capability to provide real-time data and integrate seamlessly into existing systems, the ZV900 stands out as an essential asset in the quest for cleaner, safer air.