GE ZV900 Install Duct Covers Install Filters, Charcoal filter, Metal filter

Page 20

Installation Instructions

INSTALLATION—RECIRCULATING

9 INSTALL DUCT COVERS

10 INSTALL FILTERS

Place the decorative duct covers on top of the hood.

NOTE: The inside piece has holes on one end intended for use when the hood is installed for recirculating purposes.

Be sure the vented end is at the top; the vent holes will be visible in this installation.

Mounting

screw holes

Vent holes

IMPORTANT: Check to be sure that the main ON/OFF switch next to the motor is in the ON position.

Charcoal filter

The inside duct piece must slip into the folded ends on the outer section.

Duct cover

support bracket

Upper duct cover

Duct cover

support bracket

Lower duct cover

Lower duct cover seat

Extend the inner duct upward to the ceiling bracket.

Secure duct cover to ceiling bracket with 2 screws.

Install the black charcoal filter into the center opening. Secure the filter with thumbscrews on each side.

Metal filter

Filter Lock

Tip the filter into the left or right side of the opening. Lift the filter to the opposite side and into the filter lock.

To remove the filter, pull the filter lock downward.

11FINALIZE INSTALLATION

Remove all tape and packing material.

Refer to the Owner’s Manual for operating instructions.

19

Image 20
Contents Installation Instructions Rear Wall Mounting Template Before YOU Begin Contents Installation OptionsImportant Please read carefully Power SupplyAdvance Planning Do not use flexible plastic ducting Duct FittingsFlexible ducting Remove the Packaging Tools and Materials Required not Supplied30 Max Determine Installation HeightHood 36 Min Vent hood must be installed 24″ min. 11-1/2 Hood Thumb Attachment Screws Check Installation HardwareFasteners Wood 23-7/8 DUCTWORK, Wiring Locations Install Framing for Hood SupportCeiling ducting Wall DuctingInstall Mounting Bracket Install Duct BracketCheck to be sure that the bracket is level Secure the bracket to the wallPrepare the Hood Mount the Hood Level the HoodConnect Ductwork Screw ScrewVerify that power is turned off at the source Connect ElectricalFinalize Installation Install Duct CoversInstall Filters INSTALLATION-RECIRCULATING Important Framing must be capable of supporting 100 lbsInstall Mounting Bracket Bottom view Dimension by 1″ to Facilitate installation Size and CUT Duct PieceInstall Duct Covers Install Filters Charcoal filterMetal filter Remove all tape and packing materialFor Monogram local service in your area, call
Related manuals
Manual 12 pages 60.71 Kb

ZV900 specifications

The GE ZV900 is a state-of-the-art multi-gas monitoring solution designed for both industrial and environmental applications. Known for its accuracy, reliability, and advanced features, the ZV900 plays a crucial role in ensuring compliance with safety regulations and environmental standards.

One of the standout features of the GE ZV900 is its ability to measure a wide range of gases, including but not limited to carbon dioxide (CO2), oxygen (O2), nitrogen oxides (NOx), and particulates. This versatility makes it an ideal choice for facilities that require comprehensive air quality monitoring.

The ZV900 utilizes cutting-edge technology that incorporates advanced sensors and data analysis algorithms, allowing for real-time monitoring and reporting of gas concentrations. The high precision of these sensors ensures that users receive accurate and reliable data, which is critical when making operational decisions or responding to potential hazards.

In terms of connectivity, the GE ZV900 is equipped with options that support various communication protocols, such as MODBUS, BACnet, and Ethernet. This connectivity enables seamless integration into existing automation and monitoring systems, enhancing the overall functionality of the monitoring setup. Users can also access data remotely through cloud-based platforms, facilitating easier management and analysis of air quality metrics.

Another significant characteristic of the ZV900 is its user-friendly interface. The device features an intuitive touchscreen display that allows operators to easily navigate through different settings and view real-time data. This design ensures that even personnel with minimal training can effectively use the system to monitor gas concentrations and react to alerts.

Moreover, the GE ZV900 is built with durability in mind. It is designed to withstand harsh environmental conditions, making it suitable for various applications, including power generation, manufacturing, and environmental monitoring. The robust construction ensures longevity and reduces the need for frequent maintenance.

In conclusion, the GE ZV900 is a powerful, versatile, and reliable solution for multi-gas monitoring. Its advanced technologies, user-friendly design, and wide range of applications make it an essential tool for industries focused on safety and environmental stewardship. With the capability to provide real-time data and integrate seamlessly into existing systems, the ZV900 stands out as an essential asset in the quest for cleaner, safer air.