Water Hardness Test and Calibration

Test Water Hardness

The automatic liquid dishwashing detergent dispenser (SmartDispenseTM) dispenses the optimum amount of detergent to clean the dishes. This amount of detergent introduced during each cycle is based on the soil level of the dishes and the hardness of the water. Therefore, the correct water hardness setting is very important for both optimum cleaning of dishes and detergent usage.

Prior to the first use, this dishwasher must be calibrated for water hardness. This process requires the use of a water hardness test strip (part # WD01X10295). This part can by shipped by mail.

The 4 light green stripes will change color. The harder the water, the more stripes will change from green to red.

Water hardness should be tested following the instructions on the test strip package shown above.

Note: If all stripes remain green after the test, the outcome is "0 RED". The value to be entered into the dishwasher is "1".

Convert the test reading according to the table below.

Water Hardness Test Strip Indication

Red Stripes on Strip

Value to Enter into Dishwasher

 

 

0

1

1

2

2

3

3

4

4

5

Note: 1 grain per gallon = 17.1 parts per million.

SmartDispenseTM Calibration

The calibration process will differ slightly depending on whether the dishwasher is front mount control (PDW8000 series) or top mount control (PDW9000 series).

Front Mount Control (PDW8900)

Dishwasher must be in standby mode. Close and latch the door. Press normal wash to illuminate the lights on the control panel.

1.Press Cookware pad and Delay Hours pad together and hold for 3 seconds.

2.The current hardness setting will be shown on the Time Remaining display.

3.Enter the value from the test strip using the Cookware pad to increase the value or the Normal Wash pad to decrease the value.

4.Press the Start/Reset pad to return the dishwasher to normal operation. The last displayed value will be saved as the water hardness value.

Top Mount Control (PDW9700, PDW9900)

Dishwasher must be in standby mode. Press up arrow to wake up control and illuminate the lights on the control panel.

ANTI-BACTERIAL

SPEED CYCLE

SINGLE RACK WASH

Smart Dispense

DRYING

LOW DETERGENT

COOKWARE

CHINA CYCLE

RINSE ONLY

SENSING

SANITIZED

NORMAL

PLASTIC CYCLE

 

WASHING

CLEAN

1.Press the up arrow pad and Delay Hours together and hold for 3 seconds.

2.The current hardness setting will be shown on the Time Remaining display.

3.Enter the value from the test strip using the up arrow pad to increase the value or the down arrow pad to decrease the value.

4.Press the Start/Reset pad to return the dishwasher to normal operation. The last displayed value will be saved as the water hardness value.

– 14 –

Image 14
Contents Technical Service Guide Important Safety Notice Table of Contents Model Number NomenclatureW 9 9 8 0 L 0 0 S S Serial NumberIntroduction Control Features PDW8900 SeriesSelections Enhancements Start Left Side View Component Locator ViewsPDW8900 Series Shown Inside Cabinet View PDW8900 Series Shown Door ViewFront of Dishwasher PDW9000 Series ShownPDW8900 Series Shown Bottom View Rear of DishwasherPDW8900 Series Dishwasher ComponentsDoor Panel PDW9700 Series and PDW9900 Series Keypad Assembly PDW9700 Series and PDW9900 Series Water Hardness Test Strip Indication Water Hardness Test and Calibration Test Water HardnessSmartDispenseTM Calibration Front Mount Control PDW8900To remove the reservoir SmartDispenseTMDetergent Reservoir Detergent Level Sensor To remove the pump Positive Displacement PumpApproximate Detergent Use Consumer Purge Cycle When to Purge the Bulk Dispenser TankCustomer Purge of the Bulk Dispenser Tank first time the module is activated Door Interlock SwitchDetergent/Rinse Module Middle Spray Arm Using the Dishwasher with the Upper Rack RemovedRemoval and Replacement Fill Funnel Upper Spray ArmMain Conduit Lower Spray Arm, Fine Filter, and Inlet CoverHeating Element Calibrating the Turbidity Sensor Turbidity SensorTest Drain System Smart Fill System Water Valve and Flood Switch Water Valve TestDemo Mode Wash CyclesControl Module Control Module BoardActive Vent Single Rack WashTM Normal Wash CycleCirculation Pump and Motor Wax Motor and MagnetDoor Spring Installation Service Mode Description TimeFactory Test Mode Entering Factory Test ModeSchematics and Strip Circuits Verify operation afterPDW9700 Series PDW9900 SeriesWarranty for 2005 Product For The Period GE Will ReplaceWarranty for 2006 and Later Product For The Period GE Will Replace