GE ZV421, ZV541 installation instructions Advance Planning, Power Supply

Page 5

Advance Planning

ADVANCE PLANNING

Ductwork Planning

These vent hoods are equipped for 10” round ductwork.

Determine the exact location of the vent hood.

Plan the route for venting exhaust to the outdoors.

Use the shortest and straightest duct route possible. For satisfactory performance, duct run should not exceed 150 ft. equivalent length for any duct configurations.

Refer to “Duct Fittings” chart to compute the maximum permissible length for duct runs to the outdoors.

Use rigid metal ductwork only.

Install a roof cap with damper at the exterior opening. Order the cap and any transitions needed in advance.

Ceiling Framing for Adequate Support

These vent hoods are heavy. Adequate structural support must be provided. The ceiling structure must be capable of supporting the weight of the hood and any inadvertent user contact loads (approximately 300 pounds). The hood support frame will be supported by 2 x 4 cross framing.

Accessory Frames and Duct Covers

All models are shipped with a support frame and duct covers for ceilings heights of 7’11" to 8’5".

Optional accessories include telescoping support frames and duct covers to reach 8’6” and up to 10’4” ceiling heights.

Optional accessories must be ordered with the hood and be on site before final framing and wall finishing.

Mounting the hood without a support frame The distance between the cooking surface and the bottom of the hood must be 30" to 36". In situations where the ceiling is low, the hoods may be secured directly to the ceiling without the supplied frame. Use the bottom of the supplied support frame as a template to locate the mounting holes in the top of the hood. Use shims on the ceiling joists or cross framing in the mounting hole locations. This will allow the mounting screws to engage the recessed keyhole slots in the top of the hood. See Step 2.

POWER SUPPLY

IMPORTANT - (Please read carefully)

WARNING:

FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.

ATTENTION – POUR DES

RAISONS DE SÉCURITÉ, CET APPAREIL DOIT ÊTRE CORRECTEMENT MIS À LA TERRE.

Remove house fuse or open circuit breaker before beginning installation.

Do not use an extension cord or adapter plug with this appliance. Follow National Electrical Code or prevailing local codes and ordinances.

Electrical Supply

This vent hood must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse.

Wiring must be 2 wire with ground.

If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding.

Route house wiring in the ceiling, as close to the installation location as possible. Allow additional length from ceiling joists to reach the junction box on the bottom of the hood support frame.

Connect the wiring to the house wiring in accordance with local codes.

Grounding Instructions

The grounding conductor must be connected to a ground metal, permanent wiring system, or an equipment-grounding terminal or lead on the hood.

WARNING: The improper connection of equipment-grounding

conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded.

AVERTISSEMENT

Le mauvais branchement du fil de mise

àla terre peut causer un choc électrique. En cas de doute, consulter un électricien qualifié ou un technicien pour déterminer si l’appareil est à la terre.

5

Image 5
Contents Installation Instructions Pour Faire UNE Installation Correcte For Proper InstallationTo Reduce the Risk of FIRE, USE only Metal Ductwork Faut Observer LES Regles SuivantesHood Dimensions ContentsProduct Clearances Duct Cover AccessoriesZV42I ZV54IAdvance Planning Power SupplyAccessories Determine Installation HeightFt. Ceiling SuppliedFlexible ducting Duct FittingsBe careful not to scratch the hood Tools and Materials RequiredRemove the Packaging Parts Provided Accessory PackageHardware Package Locate the parts packed with the hoodPlan the Location of the Hood and Ductwork Construct Ceiling SupportSpacing JoistAlign duct DuctFinish the Ceiling DuctworkRock Size and Install DuctworkMount Template Secure house wiring Install Accessory or Supplied Support and Duct CoversAdjust telescoping accessory frame to length Tighten the screws Install Safety Screws Install HoodConnect Duct Bumper Pads Duct Transition Attachment ScrewsConnect Electrical Install the MotorVerify that power is turned off at the source Skip this Step if Using the Supplied Duct Cover Install Filters Install RodsSlide Duct Cover Down Slide the lower duct cover down onto the hoodInstall Duct Finalize InstallationCheck Blower Safety Screw Installation ChecklistCheck appearance and installation Check Operating Sound and Proper Air-FlowGE Consumer & Industrial

ZV421, ZV541 specifications

The GE ZV541 and ZV421 are prominent offerings in the realm of multi-function medical imaging devices, widely recognized for their advanced features, robust technologies, and user-friendly characteristics that cater to the needs of healthcare professionals.

The GE ZV541 is designed primarily for a wide range of imaging applications, including vascular, cardiac, and general imaging. One of its most outstanding features is its cutting-edge imaging technology, which employs advanced digital signal processing to produce high-resolution images with exceptional clarity. This enables practitioners to make accurate diagnoses and evaluate complex conditions with confidence. The ZV541 also integrates automated image optimization algorithms, ensuring that images are consistently of high quality, regardless of the operator's experience level.

Additionally, the ZV541 offers a range of versatility with its multi-modal capabilities, allowing it to perform ultrasound imaging alongside other imaging techniques. This flexibility is critical in a busy clinical environment where different modalities might be required for patient assessment. Its user-friendly interface simplifies navigation, enabling practitioners to focus more on patient care rather than on the technical complexities of the equipment.

On the other hand, the GE ZV421 excels in providing compact and reliable imaging solutions, particularly in settings where space and portability are key considerations. It retains many of the advanced imaging capabilities of its larger counterpart while being designed for ease of transport and quick setup. The ZV421 incorporates similar digital enhancement technologies that ensure high-quality output with quick turnaround times.

Both devices are equipped with intuitive touchscreen controls that enhance the user experience, making it easier to adjust settings and quickly access frequently used features. They also come with integrated data management systems that facilitate seamless sharing and storage of patient data, complying with modern healthcare standards for efficiency and security.

In summary, the GE ZV541 and ZV421 combine state-of-the-art imaging technologies with versatility and user-friendly designs. These devices are ideal for healthcare environments that require reliable performance along with superior diagnostic capabilities. Their features not only improve workflow but also enhance the overall quality of patient care, making them invaluable tools in contemporary medical practices.