12
Installation instructions
GAS COOKTOP MODELS
Converting to a different gas type
This appliance is suitable for use with Natural gas or LPG (check the “gas type” sticker attached to the appliance). To convert from one gas type to another, you need to replace the injectors, and then adjust the minimum burner setting.
Replacing the injectors
1Remove the trivets and burners from the cooktop.
2Using a spanner, remove the injector (shown in Figs.
3Fix the warning label (supplied with the conversion kit) at the back of the cooker, near the gas inlet connections. This label states that the gas cooktop has been converted for use with LPG/ Natural gas.
Adjusting the minimum burner setting
4Follow the instructions on Page 13, ‘Adjusting the minimum burner setting’.
Important!
If you are converting the cooker from Natural gas to LPG, remove the gas pressure regulator before connecting the cooker to the gas supply and replace with the test point adaptor supplied with the conversion kit.
If you are converting the cooker from LPG to Natural gas, remove the test point adaptor before connecting the cooker to the gas supply and replace with the gas pressure regulator supplied with the conversion kit.
Notes:
- The burners are designed so that regulation of primary air is not required.
Injector
Injector
Fig. 11 Auxiliary and | Fig. 12 |