Installation instructions 13
Adjusting the minimum burner setting
Check whether the flame spreads to all burner ports when the burner is lit with the gas valve set to the minimum position. If some ports do not light, increase the minimum gas rate setting. Check whether the burner remains lit even when the gas valve is turned quickly from the maximum to the minimum position. If the burner does not remain lit, increase the minimum gas rate setting.
To adjust the minimum gas rate setting:
1Turn on the burner.
2Turn the valve to the MINIMUM position.
3 Take off the knob.
4 Using a small flat screwdriver, turn the screw (see Figs. 13 or 14) to the correct regulation.
Fig. 13 Adjusting the minimum burner setting: four-function models
GAS COOKTOP MODELS
Note: for LPG, the regulation screw is normally tightened up.
regulation screw |
OR |
regulation screw |
Fig. 14 Adjusting the minimum burner setting: seven-function models (Note: valves may vary)
Table for the choice of injectors
| Natural gas |
| LPG | |||
|
|
|
|
|
|
|
Test Point Pressure [kPa] |
| 1.0 |
| 2.75 | ||
|
|
|
|
|
|
|
| Injector |
| Gas | Injector |
| Gas |
BURNER | Orifice Dia. |
| Consumption | Orifice Dia. |
| Consumption |
|
|
|
|
|
| |
| [mm] |
| [MJ/h] | [mm] |
| [MJ/h] |
|
|
|
|
|
|
|
Auxiliary | 0.85 |
| 3.60 | 0.53 |
| 3.60 |
|
|
|
|
|
|
|
1.12 |
| 6.30 | 0.70 |
| 6.30 | |
|
|
|
|
|
|
|
1.60 |
| 12.70 | 0.95 |
| 11.90 | |
|
|
|
|
|
|
|