Thermador PRG304, PRDS48 PRDS304 and PRDS36 Dual-Fuel Ranges Figures 11, 14

Page 15

STEP 4: INSTALLING ANTI-TIP DEVICE

STEP H: Using the l/4"-20 x 1/2" Hex Head Bolt, Hex Nut and two (2) Flat Washers, securely attach the Adjustable Anti-Tip Channel to the existing hole in the flange located at the bottom rear of the range. (There are two (2) holes in the range flange, so be certain to select the hole that is on the same side as the mounting bracket.) The flat face of the channel should be flush against the underside of the range flange. From the bottom of the channel, screw the two (2) #10 x 1/2" Phillips Screws up through the first pair of holes extending beyond the rear edge of the range flange. These screws will prevent rotation of the channel. Note: A number of mounting holes are provided in the Adjustable Anti-Tip Channel. Be certain to use the hole that enables the channel to engage the mounting bracket when the range is in its final installed position. For ranges that are to be installed flush against a rear wall, use the first hole in the Adjustable Anti-Tip Channel, such that the short portion of the channel extends out from the bottom of the range flange and the long portion is hidden beneath the range. Refer to Figure 10.

STEP I: Carefully slide the range into position.

FOR THE ANTI-TIP CHANNEL TO ENGAGE THE MOUNTING BRACKET, THE REAR EDGE OF THE RANGE SIDE PANEL MUST BE WITHIN 2" OF THE VERTICAL MOUNT ING FLANGE OF THE ANTI-TIP BRACKET,

FIG. 13 PRG36 Floor Mount

PLAN VIEW

Anti-Tip Channel

O O O O'

*— Mounting Bracket

 

"T

PRG304: 2-3/4"

PRG36: 4-5/8"

±

May Be Used On Either Left or Right Side (Right Shown)

SIDE VIEW

 

-Anti-Tip Channel

Leveling Leg -

- Mounting Bracket

AND THE ADJUSTABLE MOUNTING CHAN NEL MUST BE ATTACHED TO THE APPRO PRIATE MOUNTING HOLE. REMOVE ANY LOOSE ITEMS SUCH AS GRATES AND BURNER CAPS FROM THE TOP OF THE RANGE, THEN CAREFULLY TILT THE RANGE FORWARD TO ENSURE THAT THE ANTI-TIP DEVICE ENGAGES TO PREVENT TIPPING.

PRDS304 AND PRDS36 Dual-Fuel Ranges (Figures 11, 14 and 15)

STEP A: Determine the best location for Anti- Tip Channel Mounting Bracket. The bracket may be mounted to the wall or floor behind the range, offset from side wall as indicated in the chart below and in Figures 14 and 15:

Model No. "A", Min. "B", Max.

PRDS304 5-1/2" 16-1/2"

PRDS36 6-1/2" 13-1/2"

For Model PRDS304, the dimensions shown are from the left side wall only.

For Model PRDS36, the dimensions shown are from either the left or right side wall. Locate the bracket on the side of the range that will not interfere with the gas supply line, electrical wiring, conduit or any other item.

Select either the rear wall or the floor for mounting the bracket, based upon which will provide the greatest holding strength.

Page 13

Image 15
Contents Gas Supply CorporationSmall electric oven with a bread What to do If YOU Smell GASDo not try to light any appliance If you cannot reach your gas supplier, call Fire departmentAvertissements EN Francais Avertissement Danger DE RenversementCE QUI Faire SI Vous Risques D* Electrocution LES Degats DE LA ProtrieteAvertissement TouteslescuisinieresVTrim. See Steps 2 Wall InstallationIsland Installation Ventilation RequirementsWan Cabinet ClearancesSide View 30, 36 and 48 Ranges Cabinet PreparationGAS and Electric Supply Zones Grounding plug. IT Must be PluggedModel Electrical SUPPLY, Dual Fuel Ranges Power Cord & Receptacle Junction Box & ConduitAll Ranges Removal UNPACKING, Moving and Placing the RangeUNPACKING, Moving and Placing the Range Installing ANTI-TIP Device Range Tipping Hazard ALL Ranges can TIP Important Installation Information PRG36 All-Gas RangesPrepare holes at fastener locations as identified below Step B Set the bracket on the floor and turn it Plan ViewSide View PRDS304 and PRDS36 Dual-Fuel Ranges Figures 11, 14 Prds Floor Mount Prds Wall MountGAS Requirements and Hookup Hook UPManifold Pressure 10 water column 24.9 mb Phase Unit and remove cover. Refer to For P*RDS304 rangeCupped Washer Wire Lead ConnectionGround Wire Wire ConnectionPROS36 and PRDS48 Grounding MethodPRG48 Under ANY CIRCUMSTANCES, be CUT or RemovedPRDS36/PRG36 Backguard InstallationCase 2 Electrical Connections and Grounding Backguard must be attachedTest and Adjustment Griddle 3/4 4to Grill 1/4 1/2 To Clean and Protect Exterior SurfacesGAS Supply Final Check ListPage Page Corporation Thermador