STEP 4: INSTALLING ANTI-TIP DEVICE
STEP H: Using the
STEP I: Carefully slide the range into position.
FOR THE
FIG. 13 PRG36 Floor Mount
PLAN VIEW
O O O O' | *— Mounting Bracket |
|
"T
PRG304:
PRG36:
±
May Be Used On Either Left or Right Side (Right Shown)
SIDE VIEW
| |
Leveling Leg - | - Mounting Bracket |
AND THE ADJUSTABLE MOUNTING CHAN NEL MUST BE ATTACHED TO THE APPRO PRIATE MOUNTING HOLE. REMOVE ANY LOOSE ITEMS SUCH AS GRATES AND BURNER CAPS FROM THE TOP OF THE RANGE, THEN CAREFULLY TILT THE RANGE FORWARD TO ENSURE THAT THE
PRDS304 AND PRDS36 Dual-Fuel Ranges (Figures 11, 14 and 15)
STEP A: Determine the best location for Anti- Tip Channel Mounting Bracket. The bracket may be mounted to the wall or floor behind the range, offset from side wall as indicated in the chart below and in Figures 14 and 15:
Model No. "A", Min. "B", Max.
PRDS304
PRDS36
For Model PRDS304, the dimensions shown are from the left side wall only.
For Model PRDS36, the dimensions shown are from either the left or right side wall. Locate the bracket on the side of the range that will not interfere with the gas supply line, electrical wiring, conduit or any other item.
Select either the rear wall or the floor for mounting the bracket, based upon which will provide the greatest holding strength.
Page 13