Thermador HS-HST-HSB installation instructions 2 7 1/16

Page 11

BEFORE INSTALLING HOOD

closed.

Wall Mount Installation - HS and HSB series only. (see Figure 5)

1.After the hood installation height has been determined draw a horizontal line at a distance above the cooktop equal to the desired hood installation height plus 7- 1/2”.

2.Find the centerline of the cooktop. Draw a vertical line along this centerline up to the horizontal line drawn in step 1 and draw a vertica line right and left at a distance of 12 - 5/8” to determine the mounting location of the mounting hooks shipped with the hood.

3.Fit two mounting hooks on the wall to hang the hood through the provided slots (2 wall anchors+2 hooks + 2 screws 5x45).

4.Run 8” Duct, long enough to reach the transition once the hood has been installed plus 1 1/2” inch to connect ductwork.

Fix Duct to transition with screws and seal with tape.

5.If mounted, remove the grease filter.

6.Remove 1 of 2 knockouts and install 1/2” conduit connector in j-box.

7.Hang the hood and adjust its position through the screws on the hooks.

8.Fix the hood to 4 additional point,2 on upper side, 2 on lower side (use 4 wall anchors + 4 washers + 4 screws 5x35.

HOOD WIDTH

DIM. "W" DIM. "K"

DIM. "Z"

30"

29 - 1/8"

2 - 1/2" 7 - 1/16"

36"

35 - 1/16"

2 - 1/2" 7 - 1/16"

42"

41 - 1/16"

2 - 1/2" 7 - 1/16"

48"

47 - 1/16"

2 - 1/2"

7 - 1/16"

Table 3

 

 

 

Transition

 

Side slot

 

 

for cabinet

 

 

bottom mount.

 

 

 

Top

 

 

 

screw

 

 

 

location

Top

 

Z

K

outlet

W

 

Knockouts

 

 

 

 

 

(junction box)

 

 

 

Top

 

 

Square

screw

 

 

slot

location

7 1/2"

bottom mounting

screws locations

 

W

CL

Z

 

 

K

 

Hook for wall

 

Screw for

 

installation

 

cabinet

 

25 3/16"

bottom

 

 

 

installation

7 1/2"

12 5/8"

12 5/8"

Adjusting

 

 

screw

 

CL

 

Bottom of the Hood

 

 

 

Figure 5

Page 11

Image 11
Contents Read and Save These Instructions FIRE, USE only Metal Duct Work Important Safety InstructionsEvacuateandcallthefire Department LES Instructions DE Sécurité Importantes Seulement si Parts Included with your Hood Before Installing Hood Cabinet or Soffit Preparation Appliance InstallationDucting Typical InstallationTab 2 7 1/16 67/8 Wall Mount Installation HST series Hood only see FigurePage Models VTN420B or VTN620B see figure Cabinet Installation FigureIntegral Ventilator Installation Remove the j-box cover as shown in Figure Wiring the Hood with an IntegralVentilatorWiring the Hood with a Remote Ventilator Fixing Screws number depends on hood size