Wiring the HOOD with an IntegralVentilator:
Warning: Turn off electricity at the service panel before wiring the unit.
1.Connect the Integral Ventilator molex plug connector to the connector present inside the hood as shown in Figure 9 or
Figure 10.
2.Remove the j-box cover as shown in Figure 11.
3.Remove 1 of 2 knockouts and install 1/2” conduit connector in
4.Run black, white, and green wires (#14 AWG) in 1/2” conduit from power supply to
5.Connect black, white, and green wires from power supply to black, white, and green/ yellow wires in
6.Close
Final installation steps
7.Only HSB30 and HS30 Series hoods: fit the side mould on the right side, and fix it with 3 screws as shown in Figure 12.
8.Replace filters as described in the Care & Use section of this manual.
Turn power on at service panel. Check operation of the hood.
| From Control |
| Panel |
| Motor connector |
Figure 10 | VTN 420 or VTN 620 |
From control panel
Figure 11
Figure 12