Thermador HS-HST-HSB Cabinet Installation Figure, Integral Ventilator Installation

Page 14

Cabinet Installation: (Figure 5)

Note: distances on page 10, Table 3.

1.Find the centerline of the cabinet bottom. Draw a line along this centerline from rear to front of the cabinet.

2.Draw two lines, one at a K distance from the wall, the other one at a Z distance from the previous line.

Mark 4 points , two along each line at a distance of half W from the center line, to determine the screw locations.

3.Fit 4 screws on cabinet bottom do not tighten completely but leave a space of about 1/2” from cabinet bottom surface and head screws.

4.Run 8” Duct, long enough to reach the transition once the hood has been installed plus 1 1/2” inch for connect ductwork.

Fix Duct to transition with screws and seal with tape.

5.If mounted, remove the grease filter.

6.Remove 1 of 2 knockouts and install 1/2” conduit connector in j-box.

7.Hang the hood on screws through side slots provided on hood top.

Tighten the four screws.

If possible fix the hood on the wall at 4 additional point (2 on upper side, 2 on lower side).

INTEGRAL VENTILATOR INSTALLATION

(Models VTN420B or VTN620B) (see figure 9)

The Integral ventilator can be mounted to discharge air as shown on figure A and B at page 9.

It must be fixed through the slots of the ventilator and pins with nuts of the hood.

Tighten all four nuts.

Integral ventilator fixing point

Motor

support bracket Motor connector

Figure 9

Page 14

Image 14
Contents Read and Save These Instructions Important Safety Instructions FIRE, USE only Metal Duct WorkEvacuateandcallthefire Department LES Instructions DE Sécurité Importantes Seulement si Parts Included with your Hood Before Installing Hood Appliance Installation Cabinet or Soffit PreparationTypical Installation DuctingTab 2 7 1/16 Wall Mount Installation HST series Hood only see Figure 67/8Page Models VTN420B or VTN620B see figure Cabinet Installation FigureIntegral Ventilator Installation Wiring the Hood with an IntegralVentilator Remove the j-box cover as shown in FigureWiring the Hood with a Remote Ventilator Fixing Screws number depends on hood size