Thermador HS-HST-HSB installation instructions Typical Installation, Ducting

Page 9

BEFORE INSTALLING HOOD

TYPICAL INSTALLATION

The hoods are designed for either vertical or horizontal discharge as shown in Figure A and B respectively.

The height from the countertop to the bottom of the hood is 30" to 36”.These hoods are not recommended to be used over indoor grills.

DUCTING

Provide a Round Duct having a diameter of 8” (see Figure A and B for location and Figure 1 for location on wall or cabinet bottom).

Install a 1/2” conduit from the service panel long enough to reach the hood once it is installed.

Power supply must be rated for 120V 60Hz, 15 amps (minimum).

Note - Horizontal Discharge: The Transition for this discharge direction is not supplied and must be purchased separately.

Page 9

Image 9
Contents Read and Save These Instructions FIRE, USE only Metal Duct Work Important Safety InstructionsEvacuateandcallthefire Department LES Instructions DE Sécurité Importantes Seulement si Parts Included with your Hood Before Installing Hood Cabinet or Soffit Preparation Appliance InstallationDucting Typical InstallationTab 2 7 1/16 67/8 Wall Mount Installation HST series Hood only see FigurePage Cabinet Installation Figure Integral Ventilator InstallationModels VTN420B or VTN620B see figure Remove the j-box cover as shown in Figure Wiring the Hood with an IntegralVentilatorWiring the Hood with a Remote Ventilator Fixing Screws number depends on hood size