Alto-Shaam ASF-60G, Gas Fryer manual Gas specifications, Natural Gas, Propane Gas

Page 9

The Alto-Shaam open gas fryer has been set to operate with either natural gas or propane as indicated on the fryer identification name plate.

dANGER

CONNECTING TO THE WRONG GAS

SUPPLY COULD RESULT IN FIRE OR

AN EXPLOSION CAUSING SEVERE

INJURY AND PROPERTY DAMAGE.

installation

gas specifications

The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi.

NOTE: Customer/installer must provide manual gas shut-off valve in accordance with local code requirements.

W A R N I N G

TO AVOID SERIOUS PERSONAL INJURY, installation of this appliance must conform to local, state, and national codes; the current edition of the American National Standard Z223.1, National Fuel Gas Code, and all local municipal building codes.

In Canada, installation must be in accordance with Standard CAN/CSA B 149.1 and Installation Codes - Gas Burning Appliances, and local codes.

Category I2H at 20 mbar for use in AT, DK, FI, IE, IT, PT, SE, CH.

Category I2E(20) at 20/25 mbar for use in DE, LU.

Category I2E+(20/25) at 20/25 mbar for use in BE, FR.

Category I2L(25) at 25 mbar for use in NL.

Category I3+(28-30/37)at 28-30/37 mbar for use in BE, FR, IE, IT, LU, PT, CH.

Category I3B/P(30) at 30 mbar for use in DK, FI, NL, SE.

Category I3B/P(50) at 50 mbar for use in AT, DE, CH.

Category I3P(37) at 37 mbar for use in FI, DE, IE, CH.

declared input (kw)

35.15

 

gas group

I2H(20), I2E(20), I2E+(20/25), I2L(25), I3+(28-30/37),

 

I3B/P(30), I3B/P(37), I3B/P(50), I3P(37),

I3P(50)

inlet pressure (mbar)

17.5 (NAT) and 27.5 (LP)

 

declared setting pressure at the

12.5 (NAT) and 25 (LP)

 

outlet from the gas valve (mbar)

 

 

main burner type

Infrared type with blower and venturi valve

number of injectors

1

 

main injector type

N/A

 

main injector size and markings

N/A

 

main burner aeration opening

Variable pre-set at factory

 

size

 

 

ignition

Direct spark electronic ignition

 

inlet connection

20.995 mm male thread

 

GAS PRESSURE CHART

The fryer has been factory adjusted according to the gas type specified on the fryer identification name plate.

GAS FRYER TECHNICAL SPECIFICATIONS

Natural Gas

Min. Connected Pressure

5.0" W.C.

 

1.2 kPa

Max. Connected Pressure

11.0" W.C.

 

2.74 kPa

Gas Consumption

120 CFM

 

Gross Thermal Output

120,000 Btu/hr

Propane Gas

 

 

 

 

 

 

 

 

 

 

 

 

Min. Connected Pressure

10.0" W.C.

 

2.5 kPa

Max. Connected Pressure

14.0" W.C.

 

3.5 kPa

Gas Consumption

48 CFM

 

Gross Thermal Output

120,000 Btu/hr

 

 

 

 

 

INSTALLATION REqUIREMENTS

gaS COnneCTiOn: 1/2" NPT

hOOd inSTallaTiOn iS reQuired

Check plumbing codes for proper supply line sizing to attain minimum burner manifold pressure shown:

NATURAL GAS: 5.0" W.C.

PROPANE GAS: 10.0" W.C.

(1.2 kPa)

(2.5 kPa)

MAX. RECOMMENDED

INLET PRESSURE: 11" W.C (2.74 kPa)14" W.C. (3.5 kPa) nOTe: If a flexible gas line is used, it must be AGA

approved, commercial type and at least 1/2" I.D.

Manual gas shut-off valve and restraining device must be installed per code requirements when using a quick disconnect device.

NOT FACTORY SUPPLIED

MN-35207 • Gas Fryer Operation & Care Manual • 7

Image 9
Contents ASF-60G Cleaning L I V E R Y P a C K I N GKeep this Manual in a Convenient Location for Reference Safety PROCEdURES Precautions InstallationWeight EST ASF 60 SpecificationsMinimum Clearance REqUIREMENTS Site InstallationLocate the appliance on a firm, level surface only Improper Installation MAY Result in FireN t i l a t i o n Gas specifications Natural GasPropane Gas Never USE AN Open Flame to Leak Test Leak TestingRisk of Electric Shock S t r a i n t requirements mobile equipmentE c t r i c a l requirements Hard wired modelsL/s h o r t e n i n g requirements OperationE r a t i o n Start up & general operationASF-60G N e l identification Filter key not enabledOn/Off key Temp toggle clear keyE r a t i n g the control Display Descriptions Resetting the Product CountsCheck Product Counts Exit Product CountsProgramming RecipeCode ManagerSpecificoptionsoptions SET Global Tempera S t e m programming Gramming Mode Program SUGGESTEd Frying TimesEggplant DISCONNECT Unit from Power Source bEFORE Daily cleaning & maintenanceCleaning or Servicing Thoroughly Clean Daily E a n i n gCl e a n i n g Boil out procedureControl Reset Unit troubleshooting R v i c e N t r o l troubleshootingCleaning or Servicing ExTended limiTed frypOT warranTyR v i c e ASF-60G ASF-60G Kettle Assembly 5014395 shown ASF-60G 120V electrical packages Lift Assembly 5014863 shown Control panel Assembly, ASF-60G 5013197 shown Electrical Assembly, 120V ASF-60G Electrical Assembly Limited Warranty
Related manuals
Manual 2 pages 37.7 Kb

ASF-60G, Gas Fryer specifications

The Alto-Shaam ASF-60G is a state-of-the-art food holding cabinet designed to enhance food service operations in commercial kitchens. Renowned for its exceptional performance and innovative technologies, this model is particularly popular among restaurants, catering services, and hospitality businesses that require consistent and high-quality food preservation.

One of the standout features of the ASF-60G is its unique SmartTemp technology. This advanced temperature control system ensures that food is held at precise temperatures, preventing overcooking or drying out. With the ability to adjust the temperature to the needs of various food items, operators can maintain the quality and safety of the food for extended periods.

The cabinet boasts a spacious interior that can accommodate up to 30 standard food pans, making it incredibly versatile for different types of culinary offerings. Its adjustable shelving allows for flexible organization, enabling chefs to easily access and store various meals while optimizing space within the kitchen.

Another significant characteristic of the ASF-60G is its durability. Constructed with high-quality stainless steel, the cabinet is designed to withstand the rigors of a busy kitchen environment. The robust build not only ensures longevity but also facilitates easy cleaning and maintenance, which is crucial in maintaining hygiene standards.

The Alto-Shaam ASF-60G incorporates Halo Heat technology, which utilizes gentle, even heat distribution to provide consistent holding temperatures without the use of fans. This method reduces moisture loss, preserving the texture and flavor of food items. Unlike traditional heated holding solutions, Halo Heat is energy-efficient and minimizes the need for frequent adjustments.

Additionally, ease of use is a key consideration in the design of the ASF-60G. It features an intuitive digital control panel that allows operators to monitor and adjust settings swiftly. The clear display provides real-time updates on temperature and operational status, ensuring that users can maintain optimal conditions at all times.

For those prioritizing energy efficiency, the Alto-Shaam ASF-60G is designed to minimize energy consumption while maximizing performance. This sustainable approach not only lowers operational costs but also aligns with the growing demand for environmentally conscious cooking solutions.

In conclusion, the Alto-Shaam ASF-60G offers an exceptional blend of features, advanced technologies, and durable construction. Its commitment to food quality, efficiency, and user-friendly operation positions it as a leading choice for food service professionals seeking to elevate their food holding capabilities.