Alto-Shaam 10.20ESG, 10.10ESG, 6.10ESG manual Error C ODE S a ND R Easons co ntinued

Page 28

E R R O R C O D E S

®

COMBITHERM

ERROR C ODE S A ND R EASONS (co ntinued )

Err or

Display S how s

 

When does t he e rror o ccur ?

Possible reason

Cod e

 

 

 

 

 

 

 

 

E13

Excess Steam Gen Temp

ES units only:

• Problem with water level probe.

 

 

Activated if the temperature of the steam

• Scale build-up inside steam generator.

 

 

generator probe (B-4) is higher than 248°F

 

 

 

 

 

(120°C) for 26 seconds.

• Steam element contactor is stuck.

 

 

 

 

• Connection issue with B-4 probe.

 

 

 

 

• Faulty B-4 probe.

 

 

ESi units only:

• Jumper on X-3 is improperly positioned.

 

 

Activated if the position of personality

Should be between 2-8 or, if it is a smoker,

 

 

 

jumper on X-3 is incorrect.

between 2-9.

 

 

Activated if the position of B-4 jumper is

• Jumper on X-6a is improperly positioned.

 

 

 

incorrect.

Should be between 13-14.

 

 

 

 

E15

Excess Condensate Temp

Activated if the temperature of the

• Water supply is shut off.

 

 

condensate probe (B-3) is higher than 212°F

• Faulty or plugged solenoid valve (Y-2).

 

 

(100°C) for 26 seconds.

 

 

 

 

 

 

 

• Connection issue at B-3 probe.

 

 

 

 

• Faulty B-3 probe.

 

 

 

 

E21

Oven Probe Fault

Activated if oven temperature probe (N-6) is

• Connection issue at N-6 probe.

 

 

interrupted.

• Faulty N-6 probe.

 

 

 

 

 

 

 

 

E22

Core Temp Probe Fault

Activated if cooking in Core Temp mode and

• CTC sensor is damaged.

 

 

the CTC sensor measures an excessive

4-point CTC sensor is activated, but 1-point

 

 

temperature.

 

 

CTC sensor is installed.

 

 

 

 

 

 

 

 

• Cable connection of CTC sensor is damaged.

 

 

 

 

• Hardware problem on control unit (SM).

 

 

 

 

E23

Steam Gen Probe Fault

ES units only:

• Connection issue at B-4 probe.

 

 

Activated if the steam generator probe (B-4)

• Faulty B-4 probe.

 

 

is interrupted.

 

 

 

 

 

ESi units only:

• Jumper on X-3 is improperly positioned.

 

 

Activated if the position of personality

Should be between 2-8, if it is a moker,

 

 

 

jumper on X-3 is incorrect.

between 2-9.

 

 

Activated if the position of B-4 jumper is

• Jumper on X-6a is improperly positioned.

 

 

 

incorrect.

Should be between 13-14.

 

 

 

 

E24

Bypass Probe Fault

Activated if the bypass probe (B-5) is

• Connection issue at B-5 probe.

 

 

interrupted.

• Faulty B-5 probe.

 

 

 

 

 

 

 

 

E25

Condensate Probe Fault

Activated if the condensate probe (B-3) is

• Connection issue at B-3 probe.

 

 

interrupted.

• Faulty B-3 probe.

 

 

 

 

 

 

 

 

E26

Steam Gen Safety Probe

Activated if the steam generator safety probe

• Connection issue at N-8 probe.

 

Fault

(N-8) is interrupted.

• Faulty N-8 probe.

 

 

 

 

 

 

 

 

E27

Excess Steam Gen Safety

ES units only:

• Problem with water level probe.

 

Temp

Activated if the steam generator safety probe

• Scale build-up inside steam generator.

 

 

(N-8) measures a temperature in excess of

 

 

 

 

 

266°F (130°C).

• Steam element contactor is stuck.

 

 

 

 

• Connection issue with N-8 probe.

 

 

 

 

• Faulty N-8 probe.

 

 

ESi units only:

• Jumper on X-6b is improperly positioned.

 

 

Activated if the position of N-8 jumper is

Should be between 1-2.

 

 

 

incorrect.

 

 

 

 

 

 

 

 

 

GAS CO MBI TH ERM I NSTA LLATI ON M A N UAL #MN-28676

PG. 26

 

 

 

 

Image 28
Contents Phone Inst Allati onFAX Page Deli Very CAU TIO NUnpack I NG Safety Proc Edures Preca UTI ONS DAN GERWA Rning AU TI onM M O N S P E C I F I C AT I O N S 0 E S G S P E C I F I C AT I O N S TWO 2 Cold Water Inlets Drinking Quality1 0 E S G S P E C I F I C AT I O N S Water Drain 1-1/24 E S G S P E C I F I C AT I O N S 2 0 E S G S P E C I F I C AT I O N S DIM EN SI on S H x W x DCL EAR AN CE RE Quirements GA S R EQ UI REM EN TS Water R Equi Rements1 8 E S G S P E C I F I C AT I O N S Weight Capa City Dime NS Ions H x W x DCL EAR AN CE RE Quirements GA S R EQU IR EM EN TS Wate R Q UAL ITY MI NI MUM ST AndardsNGE R Insta Llation Codes & ST Anda RDSLocation Site & Installation Requirements CA UTI onVenti Lation RE Quire Ments Positionin G O N SIT ENot E Add iti onal clea rance is nee ded for DAN GE R ANG ERDA NGE R Electr ICA L Ground ING Instr Uctio NSWA RNI NG Warn INGI P T R AY I N S TA L L AT I O N B I L E E Q U I P M E N T R E S T R a I N TSpecifications Natural Ga sPr opan e G as GAS SP Ecif ICA TIO NSN N E C T O N Ssur e test ing at pressur es in e xce ssDisc onn ect WAR NI NGEct sna Never U SE AN Open Flame to Leak Test GAS Exha UST AN GE RSure s USE a DR INK ING QUALITY, Cold Water S Upply only ContaminantWater R Equi REM Ents NPT Can manifold off of one 3/4 line To 6.2 barItem FI-23014 149F 65C WAT ER D Rainag ES TA L L AT I O N C H E C K L I S T SE Rvice Mode E RR or Codes Error C ODE S a ND R Easons co ntinued Error C ODE S a ND RE Asons cont inued Emerg Ency Operation Free Chlorine HardnessChloride AlkalinityTransportation Damage and Claims

6.10ESG, 10.20ESG, 10.10ESG specifications

Alto-Shaam, a leader in commercial kitchen equipment, has revolutionized the foodservice industry with its innovative products, particularly the 10.10ESG, 10.20ESG, and 6.10ESG models. These versatile cook and hold ovens are designed to enhance food quality while improving operational efficiency.

The 10.10ESG is an impressive model that accommodates various cooking needs, offering a generous capacity combined with precise temperature control. With the ability to operate at a maximum temperature of 325°F, it allows for consistent cooking results, ensuring that food is held at the desired temperature without drying out. This model features advanced digital controls that allow operators to set and monitor cooking cycles with ease, ensuring precise results every time.

Moving on to the 10.20ESG, this model takes cooking versatility to a new level. With its dual convection and steam cooking options, it is ideal for establishments requiring high-volume cooking. This model boasts enhanced humidity control, which helps maintain food moisture, texture, and overall quality. The 10.20ESG allows operators to cook a variety of foods—from meats to pastries—with remarkable efficiency and reliability. Its energy-efficient design not only saves on operational costs but elevates the quality and consistency of the food prepared.

The 6.10ESG is the compact version, specifically designed to cater to smaller operations without compromising on technology or performance. Despite its smaller size, this model is equipped with the same advanced digital controls and cooking technologies as the larger versions. It features a powerful heating system that ensures even cooking and browning. Ideal for restaurants, cafes, and catering services that require flexibility, the 6.10ESG shines in busy kitchen environments where space is at a premium.

Collectively, these models share several key features: the patented Halo Heat technology, which provides gentle, even cooking without direct heat, eliminates hot spots, and holds food at optimal serving temperatures. Each model also prioritizes energy efficiency, contributing to lower utility costs while maintaining exceptional performance and food quality.

In summary, Alto-Shaam’s 10.10ESG, 10.20ESG, and 6.10ESG represent the pinnacle of cooking technology designed for modern foodservice operations. Their robust features and innovative cooking methods allow for increased efficiency, improved food quality, and a significant reduction in labor costs, making them indispensable tools in any commercial kitchen.