LG Electronics LMV1630WW, LMV1630BB installation instructions Prepare The Venting Blower

Page 10

STEP 3: Prepare The Venting Blower

Your microwave oven is shipped with the blower assembled for room-vented. You need to adjust the blower if you want wall-ventedor roof-vented installation.

W A R N I N G

ELECTRICAL SHOCK HAZARD! UNPLUG UNIT BEFORE WORKING ON IT.

DO NOT PULL OR STRETCH THE BLOWER WIRING! Pulling and stretching the blower wiring could result in electrical shock.

REMOVE THE MOUNTING PLATE:

1.Remove any shipping materials and parts from inside the microwave oven. Set them aside for later use.

2.Cover the counter top or cooktop with a thick, protective covering to protect it from damage and dirt. See Figure 11. NOTE: If you have a free-standing range, disconnect

it, move it onto a piece of cardboard or hardboard and pull it away from the wall, so that you can get closer to the upper cabinet and back wall for easier measuring and drilling.

3.Remove mounting plate screw(s) (1 or 2 screws) from the mounting plate as shown and discard the screws.

See Figure 12.

4.This plate will be used as the rear mounting plate. (It will be used to locate and mark the mounting holes on the rear wall.)

5.Locate exhaust adaptor, grease filters and hardware packet.

6.At this point, remove any adhesive tape (if there is any), on the exhaust adaptor, the grease filters and the power supply cord.

ROOM-VENTED INSTALLATION:

This oven is shipped assembled for room-vented. You need to

go to STEP 4: PREPARE THE WALL & UPPER CABINET located

on page 13 .

A thick, protective

covering

Figure 11

Mounting Plate

Mounting Plate Screw(s)

(1 or 2 screws)

Control Panel Side

Mounting plate

Mounting Plate

Screws

Control Panel Side

Figure 12

– 10

Image 10
Contents Microwave Oven Your Safety First For Your SafetyThis Appliance Must be Grounded Make Sure YOU have Enough Space and Support Four 1/4 x 2 lag screws Actual Size Damper/duct connectorTwo tapping screws Actual Size Stud Finder or Thin Nail Prepare The Electrical Connection Power-Supply-Cord HoleUpper Cabinet Grounded Outlet Roof Venting Prepare The Venting SystemWall Venting Room VentingExceed 140 feet Standard Fittings Duct Length73 ft Prepare The Venting Blower Electrical Shock HAZARD! Unplug Unit Before Working on ITWALL-VENTED Installation ROOF-VENTED Installation Prepare The Wall & Upper Cabinet Drill The Holes In The Wall And Upper Cabinet Rear Wall TemplateInstall The Mounting Plate Oven Must Be Connected To At Least One Wall StudFor Wall-Vented Attach The Oven To The Wall Cord