INSTALLATION INSTRUCTIONS

ELECTRICAL CONNECTIONS

IMPORTANT SAFETY INSTRUCTIONS

Be sure your cooktop is installed and grounded properly by a qualified installer or service technician.

This cooktop must be electrically grounded in accordance with local codes or, in their absence, with the National Electrical Code ANSI/NFPA No. 70, latest edition in the United States.

PROVIDING THE ELECTRICAL CONNECTION

Install the junction box under the cabinet and run 120/240 or 120/208 volt, AC wire from the main circuit panel.

NOTE: DO NOT connect the wire to the circuit panel at this time.

WARNING: The electrical power to the cooktop must be shut off while line connections are being made. Failure to do so could result in serious injury or death.

ELECTRICAL REQUIREMENTS

Observe all governing codes and local ordinances.

A 3-wire or 4-wire single-phase 120/240 or 120/208 volt, 60 Hz AC-only electrical supply is required on a separate circuit fused on both sides of the line (time-delay fuse or circuit breaker is recommended). DO NOT fuse neutral. The fuse size must not exceed the circuit rating of the appliance specified on the nameplate.

This unit can consume up to 7,400W at 240 VAC. A 40 Amp circuit breaker with wire gauge #8 AWG must be used.

NOTE: Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance with the National Electrical Code ANSI/NFPA No. 70, latest edition, and local codes and ordinances.

The appliance should be connected to the fused disconnect (or circuit breaker) box through flexible armored or nonmetallic sheathed cable. The flexible armored cable extending from this appliance should be connected directly to the grounded junction box. The junction box should be located as shown on page 22 with as much slack as possible remaining in the cable between the box and the appliance, so it can be moved if servicing is ever necessary.

A suitable strain relief must be provided to attach the flexible armored cable to the junction box.

WARNING: An extension cord must not be used with this appliance. Such use may result in a fire, electrical shock, or other personal injury.

ELECTRICAL CONNECTIONS (cont.)

ELECTRICAL CONNECTION

Connect the flexible armored cable that extends from the surface unit to the junction box using a suitable strain relief at the point the armored cable enters the junction box. Then make the electrical connection as follows.

LGE Internal Use Only

- 13 -

Copyright © 2007 LG Electronics. Inc. All right reserved.

 

 

Only for training and service purposes

Image 13
Contents Ceramic Glass Induction Cooktop Website http//biz.lgservice.comForward Safety Precautions Safety PrecautionsImportant Notice Radio Interference Important Safety Notice Electrical Safety Safety PrecautionsSafety During USE Child SafetySwitch off the Cooking Zones after use Do not use the cooktop to heat the roomSafety When Cleaning Safety During USERead and Follow this Safety Information Carefully HOW to Avoid Damage to the ApplianceCook Meat and Poultry Thoroughly Disposal of OLD AppliancesContents Description SpecificationsBefore YOU Begin Installation InstructionsUnpacking the Cooktop Read these instructions completely and carefullyImportant Installation Information Preparing the Installation LocationModel Dimensions and ClearancesElectrical Connections Important Safety InstructionsProviding the Electrical Connection Electrical RequirementsElectrical ground is required on this appliance Wire Grounded Junction BOX Cooktop InstallationFinal Check Preferred installation Alternative installationModel and Serial Number Location Induction Cooking InductionSelecting Cookware HOW Induction Cooking WorksUSE FLAT-BOTTOMED Cookware Avoiding ScratchesFor Best Results Tips for Saving EnergySelecting the Proper PAN Size Cookware Selection and PlacementCorrect IncorrectCleaning the Cooktop Cleaning and CareGeneral Cleaning Problem SoilsParts and Features of Your Cooktop Description of FeatureTouch Control Features Setting the Controls Before Using the CooktopOperating Instructions To adjust the power level Setting the Power LevelTo turn off the cooking zone Activating Power Boost Power BoostWarm To activateSetting Function Used for Power Level GuideUsing the Timer Using the Bridge Cooking ZonesSetting the Timer Canceling the TimerOther Functions Using Child LockElectric Circuit Drawing Disassembly DisassemblyCeramic Glass Part Burner assembly Controller assembly IH module assembly Power harness assembly Terminal block and power cord assembly Burner assembly left Burner assembly right Controller assembly key PCB Controller assembly main PCB IH module assembly Induction board IH module assembly Induction board IH module assembly fan IH module assembly filter boardNo Power / No Trouble ShootingCeramic Glass BrokenHeating is not IHInductionWorking E1 displayHob does not work Flashing HProperly Induction Improper working of controlModel LCE30845 Exploded ViewEALHF1