INSTALLATION INSTRUCTIONS
Electrical ground is required on this appliance.
This appliance is manufactured with a supply wire and a frame connected green or bare copper grounding wire.
NOTE TO ELECTRICIAN: The armored cable leads supplied with the appliance are
WARNING: DO NOT ground to a gas supply pipe. DO NOT connect to electrical power supply until appliance is permanently grounded. Connect the ground wire before turning on the power.
WARNING: This appliance is equipped with a copper conductor flexible cable. If connection is made to aluminum house wiring, use only special connectors which are approved for joining copper and aluminum wires in accordance with the National Electrical Code and local codes and ordinances. Improper connection of aluminum house wiring to copper leads can result in a short circuit or fire. Follow the connector manufacturer’s recommended procedure closely.
WHERE LOCAL CODES PERMIT CONNECTING THE
Observe all governing codes and local ordinances.
Disconnect the power supply.
At the circuit breaker box, fuse box or junction | White wire |
| |
box, connect appliance and power supply cable | (neutral) |
| |
Red |
| ||
wires as shown. |
| ||
wires | Black | ||
WARNING: You may not ground the cooktop |
| wires | |
|
| ||
through the neutral (white) wire if |
|
| |
cooktop is used in a new branch |
| Junction box | |
circuit installation (1996 NEC), |
| ||
|
| ||
mobile home, recreational vehicle, |
| ||
or where local codes do not permit | Green wire (ground) | ||
connector | |||
| |||
grounding to the neutral (white) | Cable from cooktop |
| |
wire. When grounding to the neutral |
|
|
(white) wire is prohibited, you must use a
Copyright © 2007 LG Electronics. Inc. All right reserved. | - 14 - | LGE Internal Use Only |
Only for training and service purposes |
|
|