2. Faults
2-1. Power
| Problems | Causes |
|
|
| Checks | Measures | Remarks | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| No power on | - Power cord cut. | - Check the voltage with tester. |
| ||||||||||||
| outlet. | - Faulty connector insertion. | - Check visually. |
| ||||||||||||
|
| - Faulty connection between plug | - Check visually. | - Reconnect the connecting parts. |
| |||||||||||
|
| and adapter. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Fuse blows out. | - Short circuit by wrong connection. | - Check the fuse with tester | - Find and remove the cause of | - Replace with rated | |||||||||||
|
| - Low voltage products are | or visually. | problem(ex. short, high voltage, | fuse after confirming | |||||||||||
|
| connected to high voltage. | - Check the input volt are with tester | low voltage). | its specification. | |||||||||||
|
| - Short circuit by insects. | (between power cord and products). | - Replace with rated fuse. |
| |||||||||||
|
| - Electricity leakage. | - Check the resistance of power cord |
| ■ If fuse blowns out | |||||||||||
|
| - High voltage. | with testerf (if it is 0Ω, it is shorted). |
| frequently, reconfirm | |||||||||||
|
| - Short circuit of components |
|
|
|
|
|
|
|
|
|
|
|
|
| the cause and prevent. |
- |
| (tracking due to moisture and dust |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
55 - |
| penetration). |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Problems | Causes |
|
|
| Checks | Measures | Remarks | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Compressor | - Faulty PTC. | - Check the resistance. | - If resistance is infinite, replace it |
| |||||||||||
| does not |
| Vlaue:∞ is defective. | with new one. |
| |||||||||||
| operate. |
|
|
|
|
|
|
|
|
|
|
|
|
| - If it is not infinite, it is normal. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| - Check other parts. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| - Compressor is frozen. | - If compressor assembly parts are | - During forced operation: |
| |||||||||||
|
|
| normal(capacitor, PTC, OLP), | - Operates: Check other parts. |
| |||||||||||
|
|
| apply power directly to the | - Not operate: Replace the frozen |
| |||||||||||
|
|
| compressor to force operation. | compressor with new one, weld, |
| |||||||||||
|
|
|
|
|
|
| Auxiliary winding |
|
|
|
|
| evacuate, and recharge refrigerant. |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| Main winding |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| Power |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| OLP |
| It starts as soon as it is | • Refer to weld repair procedures. |
| |||||||||
|
|
|
|
| contacted. |
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|