ICEMAKER AND DISPENSER WORKING PRINCIPLES AND REPAIR
1.This is a forced operation for TEST, Service, cleaning, etc. It is operated by pressing and holding the Water amount selection button for 3 seconds.
2.The test works only in the Icemaking Mode. It cannot be entered from the Harvest or Fill mode. (If there is an ERROR, it can only be checked in the TEST mode.)
3.Caution! If the test is performed before water in the ice tray is frozen, the ejector will just pass through the water. When the Fill mode begins (Stage 4), unless the water supply has been shut off, added water will overflow into the ice bin. If the control doesn’t operate normally in the TEST mode, check and repair as needed.
4.After water is supplied, the normal CYCLE is followed: icemaking → Harvest → Fill → Park Position.
5.After Stage 5 is completed, the Ice Maker returns to MICOM control. The time needed to supply water resets to the pre- test setting.
6.This icemaker function test takes about 90 seconds in case, there aren’t ices in the ice tray. If there are ices in the ice tray, it can take more than 90 seconds.
Diagnosis TABLE
STAGE | ITEMS | INDICATOR | REMARKS | |||||||
|
|
|
|
|
|
|
|
|
| |
1 | HEATER |
|
|
|
|
|
|
| Five seconds after heater starts, a | |
|
|
|
|
|
|
| heater will go off if the temperature by | |||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| sensor is higher than 10°C | |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
2 | MOTOR |
|
|
|
|
|
|
| Five seconds after heater starts, you | |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| can confirm that a motor is moving. | |||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
| HALL IC I |
|
|
|
|
|
|
| After the icemaker detects that ice has been | |
3 | (detection of |
|
|
|
|
|
|
| made, the motor and heater are off but on | |
|
|
|
|
|
|
| ||||
| position) |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| standby until the cycle is cancelled. | ||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
4 | HALL IC II |
|
|
|
|
|
|
| You can confirm HALL IC detection of | |
(detection of |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| position. | |||
|
|
|
|
|
|
| ||||
| position) |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
5 | VALVE |
|
|
|
|
|
|
| Two seconds after detection of initial | |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| position, you can confirm that valve is on. | |||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
6 | Reset | Return to Status prior to | Five seconds after fifth stage is completed, | |||||||
TEST MODE | The icemaker resets to initial status. | |||||||||
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
3. Defect diagnosis function
NO | DIVISION | INDICATOR | CONTENTS | REMARKS | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
1 | Normal | Mark time to | None | Display switch | |||||||
| supply | operates properly | |||||||||
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
2 | Icemaking |
|
|
|
|
|
|
| Open or | Make sure that the wire | |
|
|
|
|
|
|
| |||||
Sensor |
|
|
|
|
|
|
| on each sensor is | |||
| malfunction |
|
|
|
|
|
|
|
| connected. | |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
ERROR indicators in table can be checked only in TEST mode.